Skip to main content
snowflakeaircon.sg
WhatsApp

5.0onGoogle&Carousell

15,000+ jobs completed

Daikin Aircon P1 Error Code

Confirm the listed meaning of Daikin P1, note the unit that shows the code and its model, and match the service manual before diagnosis. Match the model first; same-looking codes can point to different rows.

What does Daikin P1 mean?

Daikin P1 is listed as power voltage imbalance or inverter PCB, power-supply voltage imbalance, and INV1 unbalanced power-supply voltage in fault lists for more than one model family, including VRV X RXQ-A(N)R cooling only, VRV IV+ REYQ / REMQ heat recovery, VRV 5-S RXYSA R32, VRV 5 Heat Recovery REMA / REYA R32, VRV 5 Heat Pump RYMA / RXYA R32, and ERA-AYF AHU / air curtain. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.

What to do now

Use these steps to record evidence and match the installed model to its service manual before diagnosis or a repair quote.

  • Record P1 and match the service manual

    Record P1 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.

  • No manufacturer reset steps listed for P1

    Capture the complete P1 error code and model stickers first. The manufacturer lists the meaning but no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.

  • Send these to us

    P1 error code, a clear display photo, Daikin indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared

Choose the listing that matches your unit

The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.

  • Code
    SkyAir
    What it means
    Power voltage imbalance or inverter PCB
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    VRV X RXQ-A(N)R cooling only
    What it means
    Power-supply voltage imbalance
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.
  • Code
    P1-01 - master / P1-02 - slave 1 / P1-03 - slave 2
    What it means
    INV1 unbalanced power-supply voltage
    What to check first
    Check whether the power supply is within range. The alternating P1-01 display belongs to the master outdoor unit.
  • Code
    P1-07 - master / P1-08 - slave 1 / P1-09 - slave 2
    What it means
    INV2 unbalanced power-supply voltage
    What to check first
    Check whether the power supply is within range. The alternating P1-07 display belongs to the master outdoor unit.
  • Code
    VRV 5-S R32 - P1 / VRV 5 Heat Recovery R32 - P1 / VRV 5 Heat Pump R32 - P1
    What it means
    Unbalanced inverter power-supply voltage
    What to check first
    Check that the inverter power supply is within its specified range.
  • Code
    ERA-AYF AHU / air curtain
    What it means
    Inverter supply-voltage imbalance (P1-01)
    What to check first
    Match this meaning to your installed model and the unit that shows the code, then use the checks below.

Guidance for your model

Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.

  • Detail
    Singapore / model note
    What it says
    Official Daikin SM-TS3 self-diagnosis row. Manual causes: Open phase; Interphase voltage imbalance; Defective capacitor in the main circuit.
  • Detail
    Singapore / model note
    What it says
    Official Daikin RXQ6-48A(N)R cooling-only service-manual row. Confirm the installed model and matching regional manual before diagnosis; this source is not claimed as universal across every Daikin VRV generation.
  • Detail
    Singapore / model note
    What it says
    Official Daikin 4PEN561154-1C overview row for REYQ8~20 and REMQ5U7Y1B VRV IV+ heat-recovery systems. The guide refers technicians to the service manual for the complete code list and detailed troubleshooting.

What to check before repair

The manufacturer's fault table gives the code's meaning, not a repair procedure. Capture evidence first; model-specific tests belong to the matching service manual.

  • You can check
    Photograph the complete P1 error code before taking any action.
    Technician should confirm
    Confirm P1 exactly and record which controller, gateway, or unit reported it.
  • You can check
    Capture the Daikin indoor and outdoor model stickers and identify which controller or unit reported it.
    Technician should confirm
    Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope.
  • You can check
    The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action.
    Technician should confirm
    Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.

Source-bounded repair decision

Daikin P1 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.

  • Whether the reporting controller or unit and exact installed model are confirmed.

  • What the matching service-manual procedure and measured tests show.

  • Whether the proposed repair names the evidence for the failed part or condition.

Daikin P1 questions

What does the Daikin P1 error mean?
Daikin P1 is listed as power voltage imbalance or inverter PCB, power-supply voltage imbalance, and INV1 unbalanced power-supply voltage in fault lists for more than one model family, including VRV X RXQ-A(N)R cooling only, VRV IV+ REYQ / REMQ heat recovery, VRV 5-S RXYSA R32, VRV 5 Heat Recovery REMA / REYA R32, VRV 5 Heat Pump RYMA / RXYA R32, and ERA-AYF AHU / air curtain. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
Can I fix a Daikin P1 error myself?
No. P1 needs a technician's measurement before parts are decided. Photograph the complete P1 error code before taking any action. Capture the Daikin indoor and outdoor model stickers and identify which controller or unit reported it.
Is it safe to keep running the aircon with a P1 error?
Record P1 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.
What causes a Daikin P1 error?
Daikin P1 has a listed meaning that depends on the exact model and on which unit shows the code. Use the decoder on this page before assuming a specific cause.
Will a Daikin P1 error need a repair or a full replacement?
Daikin P1 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.
What should I send a technician about a Daikin P1 error?
Before booking, send: P1 error code, a clear display photo, Daikin indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared.

Where to go next

Confirm the fault

Share the error code, model number and symptoms so we can assess the likely cause.

Not the right code?

Browse the full Daikin list or check a few codes in the same fault category.

Read next

Use this quote-check guide only after the matching service manual identifies the diagnostic path.