Daikin Aircon F3 Error Code

Daikin F3 means high temperature discharge pipe control on EZi, iSmart ENVi and iSmile and other models. Do not reset F3; the manufacturer gives no customer reset procedure.

What it means
High temperature discharge pipe control on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for F3; match the model first.
Is it serious?
Yes. Daikin F3 is a high-severity refrigerant or pressure fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Do not reset F3; the manufacturer gives no customer reset procedure. Note the code and arrange diagnosis against the matching service manual. Any homeowner step for F3 depends on which model you have.
Is it worth repairing?
Whether Daikin F3 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the refrigerant circuit. A leak has to be found and sealed before any gas goes in, and the leak's location sets most of the cost. The code names the fault, not the failed part, so measure before you decide on F3.Daikin by age, from our Daikin page:
Daikin repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsAlmost always worth repairing.
5–8 yearsRepair is still the default for most faults.
8–12 yearsDepends on the fault.
Over 12 yearsMajor component failures usually favour replacement.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Daikin F3 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Daikin F3 Mean?

Daikin F3 means high temperature discharge pipe control on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for F3; match the model first.

What Causes Daikin F3?

Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists 3 causes for Daikin F3.

  • Defective discharge pipe thermistor.

  • Abnormal discharge pipe temperature.

  • Defective outdoor unit control PCB.

Which Daikin F3 Meaning Matches Your Unit?

Daikin F3 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.

  • Model / series
    EZi
    What it means
    High temperature discharge pipe control
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
  • Model / series
    General RA self-diagnosis guide
    What it means
    Malfunction of discharge pipe temperature
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
  • Model / series
    VRV X RXQ-A(N)R cooling only
    What it means
    Discharge-pipe temperature abnormality
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
Show 4 more meanings
  • Model / series
    F3-01 - master / F3-03 - slave 1 / F3-05 - slave 2
    What it means
    Discharge temperature too high at R21T or R22T because a stop valve is closed or refrigerant is short
    What to check first
    Open the stop valves and check the refrigerant amount. The alternating F3-01 display belongs to the master outdoor unit.
  • Model / series
    F3-20 - master / F3-21 - slave 1 / F3-22 - slave 2
    What it means
    Compressor-casing temperature too high at R15T because a stop valve is closed or refrigerant is short
    What to check first
    Open the stop valves and check the refrigerant amount. The alternating F3-20 display belongs to the master outdoor unit.
  • Model / series
    VRV 5-S R32 - F3 / VRV 5 Heat Recovery R32 - F3 / VRV 5 Heat Pump R32 - F3
    What it means
    Outdoor discharge-temperature malfunction
    What to check first
    Check for a closed outdoor stop valve or insufficient refrigerant charge.
  • Model / series
    ERA-AYF AHU / air curtain
    What it means
    Discharge-pipe or compressor-casing temperature too high (F3-01/20)
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.

What Does a Technician Check for Daikin F3?

Before quoting parts for Daikin F3, a technician should confirm F3 exactly and record which controller, gateway, or unit reported it.

  • Match the indoor and outdoor model stickers, and the unit that shows the code, to the models the manual covers.

  • Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.

Will Daikin F3 Need a Repair or a New Unit?

Daikin F3 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.

Daikin F3 Questions

What does the Daikin F3 error code mean?
Daikin F3 means high temperature discharge pipe control on EZi, iSmart ENVi and iSmile and other models, according to Daikin CTKC25/35WVMG operation manual. Other Daikin models list a different meaning for F3; match the model first. The code names the fault the unit has detected, not the failed part.
Is it safe to keep running an aircon showing Daikin F3?
Treat Daikin F3 as a fault to diagnose, not a display to clear. Do not reset F3; the manufacturer gives no customer reset procedure. Note the code and arrange diagnosis against the matching service manual. Note the F3 display and when it appeared.
What causes Daikin F3?
Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists these causes for Daikin F3: defective discharge pipe thermistor; abnormal discharge pipe temperature; defective outdoor unit control PCB. A technician tests each one on your unit before replacing any part. The code alone does not say which of them has failed.
Is Daikin F3 worth repairing?
Whether Daikin F3 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the refrigerant circuit. A leak has to be found and sealed before any gas goes in, and the leak's location sets most of the cost.
How much does it cost to find out what is causing Daikin F3 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Daikin F3 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.

Where to Go Next

Confirm the Fault

Message us the code and what the unit is doing, and we tell you the likely cause.

Not the Right Code?

Browse the full Daikin list or check a few codes in the same fault category.

Read Next

Use this quote-check guide only after the matching service manual identifies the diagnostic path.