Daikin L4 means high temperature at inverter circuit heatsink on EZi, iSmart ENVi and iSmile and other models. Do not reset L4; the manufacturer gives no customer reset procedure.

What it means
High temperature at inverter circuit heatsink on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for L4; match the model first.
Is it serious?
Yes. Daikin L4 is a high-severity control board fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Do not reset L4; the manufacturer gives no customer reset procedure. Note the code and arrange diagnosis against the matching service manual. Any homeowner step for L4 depends on which model you have.
Is it worth repairing?
Whether Daikin L4 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in a control board. A failed board is replaced, not repaired, so the board's price and availability for the model decide it. The code names the fault, not the failed part, so measure before you decide on L4.Daikin by age, from our Daikin page:
Daikin repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsAlmost always worth repairing.
5–8 yearsRepair is still the default for most faults.
8–12 yearsDepends on the fault.
Over 12 yearsMajor component failures usually favour replacement.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Daikin L4 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Daikin L4 Mean?

Daikin L4 means high temperature at inverter circuit heatsink on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for L4; match the model first.

What Causes Daikin L4?

Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists 2 causes for Daikin L4.

  • Fin temperature rise due to short circuit.

  • Defective fin thermistor.

Which Daikin L4 Meaning Matches Your Unit?

Daikin L4 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.

  • Model / series
    EZi
    What it means
    High temperature at inverter circuit heatsink
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
  • Model / series
    General RA self-diagnosis guide
    What it means
    Malfunction of inverter radiation fin temperature rise
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
  • Model / series
    VRV X RXQ-A(N)R cooling only
    What it means
    Inverter radiation-fin temperature rise abnormality
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
Show 2 more meanings
  • Model / series
    VRV 5-S R32 - L4 / VRV 5 Heat Recovery R32 - L4 / VRV 5 Heat Pump R32 - L4
    What it means
    Inverter-fin temperature abnormality
    What to check first
    Record the displayed code, unit type, and serial number for qualified diagnosis.
  • Model / series
    Sky Air FNA R32 - L4 (test-run diagnostic)
    What it means
    An air inlet or outlet is blocked
    What to check first
    Confirm the indoor model is FNA25~60A2VEB(9), record the controller that shows the code, and follow the matching Daikin service procedure.

What Does a Technician Check for Daikin L4?

Before quoting parts for Daikin L4, a technician should confirm L4 exactly and record which controller, gateway, or unit reported it.

  • Match the indoor and outdoor model stickers, and the unit that shows the code, to the models the manual covers.

  • Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.

Will Daikin L4 Need a Repair or a New Unit?

Daikin L4 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.

Daikin L4 Questions

What does the Daikin L4 error code mean?
Daikin L4 means high temperature at inverter circuit heatsink on EZi, iSmart ENVi and iSmile and other models, according to Daikin CTKC25/35WVMG operation manual. Other Daikin models list a different meaning for L4; match the model first. The code names the fault the unit has detected, not the failed part.
Is it safe to keep running an aircon showing Daikin L4?
Treat Daikin L4 as a fault to diagnose, not a display to clear. Do not reset L4; the manufacturer gives no customer reset procedure. Note the code and arrange diagnosis against the matching service manual. Note the L4 display and when it appeared.
What causes Daikin L4?
Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists these causes for Daikin L4: fin temperature rise due to short circuit; defective fin thermistor. A technician tests each one on your unit before replacing any part. The code alone does not say which of them has failed.
Is Daikin L4 worth repairing?
Whether Daikin L4 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in a control board. A failed board is replaced, not repaired, so the board's price and availability for the model decide it.
How much does it cost to find out what is causing Daikin L4 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Daikin L4 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.