Daikin Aircon U0 Error Code

Daikin U0 means refrigerant shortage on EZi, iSmart ENVi and iSmile and other models. Do not reset U0; the manufacturer gives no customer reset procedure.

What it means
Refrigerant shortage on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for U0; match the model first.
Is it serious?
Yes. Daikin U0 is a high-severity refrigerant or pressure fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Do not reset U0; the manufacturer gives no customer reset procedure. Note the code and arrange diagnosis against the matching service manual. Any homeowner step for U0 depends on which model you have.
Is it worth repairing?
Whether Daikin U0 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the refrigerant circuit. A leak has to be found and sealed before any gas goes in, and the leak's location sets most of the cost. The code names the fault, not the failed part, so measure before you decide on U0.Daikin by age, from our Daikin page:
Daikin repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsAlmost always worth repairing.
5–8 yearsRepair is still the default for most faults.
8–12 yearsDepends on the fault.
Over 12 yearsMajor component failures usually favour replacement.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Daikin U0 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Daikin U0 Mean?

Daikin U0 means refrigerant shortage on EZi, iSmart ENVi and iSmile and other models. Other Daikin models list a different meaning for U0; match the model first.

What Causes Daikin U0?

Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists 3 causes for Daikin U0.

  • Refrigerant shortage or clogged piping.

  • Defective thermistor.

  • Defective low pressure sensor.

Which Daikin U0 Meaning Matches Your Unit?

Daikin U0 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.

  • Model / series
    EZi
    What it means
    Refrigerant shortage
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
  • Model / series
    General RA self-diagnosis guide
    What it means
    Shortage of refrigerant
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
  • Model / series
    VRV X RXQ-A(N)R cooling only
    What it means
    Refrigerant shortage warning
    What to check first
    Match this meaning to your model and the unit that shows the code, then use the checks below.
Show 2 more meanings
  • Model / series
    VRV 5-S R32 - U0 / VRV 5 Heat Recovery R32 - U0 / VRV 5 Heat Pump R32 - U0
    What it means
    Abnormal low-pressure drop or faulty expansion valve
    What to check first
    Record the displayed code, unit type, and serial number for qualified diagnosis.
  • Model / series
    Sky Air FNA R32 - U0 (test-run diagnostic)
    What it means
    A refrigerant stop valve is closed
    What to check first
    Confirm the indoor model is FNA25~60A2VEB(9), record the controller that shows the code, and follow the matching Daikin service procedure.

What Does a Technician Check for Daikin U0?

Before quoting parts for Daikin U0, a technician should confirm U0 exactly and record which controller, gateway, or unit reported it.

  • Match the indoor and outdoor model stickers, and the unit that shows the code, to the models the manual covers.

  • Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.

Will Daikin U0 Need a Repair or a New Unit?

Daikin U0 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.

Daikin U0 Questions

What does the Daikin U0 error code mean?
Daikin U0 means refrigerant shortage on EZi, iSmart ENVi and iSmile and other models, according to Daikin CTKC25/35WVMG operation manual. Other Daikin models list a different meaning for U0; match the model first. The code names the fault the unit has detected, not the failed part.
Is it safe to keep running an aircon showing Daikin U0?
Treat Daikin U0 as a fault to diagnose, not a display to clear. Do not reset U0; the manufacturer gives no customer reset procedure. Note the code and arrange diagnosis against the matching service manual. Note the U0 display and when it appeared.
What causes Daikin U0?
Daikin Simple Self-Diagnosis by Malfunction Code (SM-TS3) lists these causes for Daikin U0: refrigerant shortage or clogged piping; defective thermistor; defective low pressure sensor. A technician tests each one on your unit before replacing any part. The code alone does not say which of them has failed.
Is Daikin U0 worth repairing?
Whether Daikin U0 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the refrigerant circuit. A leak has to be found and sealed before any gas goes in, and the leak's location sets most of the cost.
How much does it cost to find out what is causing Daikin U0 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Daikin U0 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.

Where to Go Next

Confirm the Fault

Message us the code and what the unit is doing, and we tell you the likely cause.

Not the Right Code?

Browse the full Daikin list or check a few codes in the same fault category.

Read Next

Use this quote-check guide only after the matching service manual identifies the diagnostic path.