Daikin aircon P3 error code

Use this Daikin P3 error code guide to decide when to stop resetting, what to capture, and what to check before parts are quoted.

What does Daikin P3 mean?

Daikin P3 is listed as malfunction of thermistor in switch box in Ceiling Cassette, Ceiling Suspended, Inverter Split rows such as General RA self-diagnosis guide, SkyAir. The loaded row is source-backed by official diagnostic material. Confirm the exact model, series, or signal row before accepting a parts quote.

  • Open, shorted, displaced, or out-of-range thermistor or pressure-sensor reading.

  • Loose sensor connector, damaged sensor harness, or water-affected wiring.

  • PCB input fault after the sensor and wiring readings are confirmed.

What to do now

Use these steps before another reset, sensor check, or PCB quote.

  • Treat it as a fault signal

    If P3 returns or cooling is still abnormal, stop treating it as a simple reset issue.

  • Reset P3 once

    Capture the P3 display first, then power-cycle once only and note whether the same fault returns.

  • Send these to us

    P3 error code, a clear display photo, Daikin model stickers, affected rooms, reset result, and when the fault appears

Source-specific guidance

These diagnostic-reference notes help match the code to the exact model. Electrical, refrigerant, wiring, resistance, and component checks are technician work, not DIY steps.

Source detailWhat it says
Source repair actionStop the system if it smells burnt, leaks, or trips power; note the exact model and code before booking diagnosis.
Singapore / model noteOfficial Daikin SM-TS3 self-diagnosis row. Manual causes: Defective thermistor connection; Defective reactor thermistor; Defective inverter PCB.

What to check before repair

Use this split to separate safe evidence capture from the tests a technician should prove before quoting parts.

You can checkTechnician should confirm
Before resetting P3, take a clear display photo.Confirm which sensor P3 maps to on the exact model table.
Capture the Daikin indoor and outdoor model stickers so the correct family row is used.Measure the sensor value against the service-manual resistance or voltage range.
Note whether one room, several rooms, or the whole system is affected, plus whether it returns after one reset.Check connector condition, harness continuity, and PCB input before replacing boards.

What changes the next step

These clues decide whether the first check is room-side, shared outdoor-side, refrigerant-side, source-table, or model-family confirmation.

What you seeWhat it points to
Only one indoor unit shows P3.The affected room, indoor board path, wiring route, or local component should be checked first.
Several rooms or the outdoor unit show the same P3 fault.The shared outdoor side, power path, communication trunk, or refrigerant circuit needs priority checking.
The fault appears immediately even before the unit cools properly.Sensor value, connector, harness, and PCB input should be tested in that order.
The model family is different from the row you found online.Use the model or series filter first; same-looking codes can still belong to different diagnostic tables.
The model belongs to Ceiling Cassette, Ceiling Suspended, Inverter Split rows such as General RA self-diagnosis guide, SkyAir.The loaded row is source-backed by official diagnostic material. Use the matching source row before quoting parts.

Sensor or PCB decision

Daikin P3 is usually repair-first if a sensor or harness reading is confirmed. Board replacement should wait until the sensor circuit is tested.

  • Sensor replacement is usually targeted when resistance or voltage readings are out of range.

  • Harness or connector damage can look like a sensor fault until continuity is checked.

  • PCB replacement is a later step if the sensor and wiring test correctly.

Daikin P3 questions

What does the Daikin P3 error mean?
Daikin P3 is listed as malfunction of thermistor in switch box in Ceiling Cassette, Ceiling Suspended, Inverter Split rows such as General RA self-diagnosis guide, SkyAir. The loaded row is source-backed by official diagnostic material. Confirm the exact model, series, or signal row before accepting a parts quote.
Can I fix a Daikin P3 error myself?
No. P3 needs a technician's measurement before parts are decided. Before resetting P3, take a clear display photo. Capture the Daikin indoor and outdoor model stickers so the correct family row is used.
Is it safe to keep running the aircon with a P3 error?
If P3 returns or cooling is still abnormal, stop treating it as a simple reset issue.
What causes a Daikin P3 error?
Open, shorted, displaced, or out-of-range thermistor or pressure-sensor reading. Loose sensor connector, damaged sensor harness, or water-affected wiring. PCB input fault after the sensor and wiring readings are confirmed.
Will a Daikin P3 error need a repair or a full replacement?
Daikin P3 is usually repair-first if a sensor or harness reading is confirmed. Board replacement should wait until the sensor circuit is tested.
What should I send a technician about a Daikin P3 error?
Before booking, send: P3 error code, a clear display photo, Daikin model stickers, affected rooms, reset result, and when the fault appears.

Confirm the fault

Share the error code, model number and symptoms so we can assess the likely cause.

Not the right code?

Browse the full Daikin list or check a few codes in the same fault category.

Ready to get started?

Tell us what’s going on. Symptoms, setup, photos, anything we should know. We’ll assess and come back with the right next step.