Midea Aircon PC 00 Error Code

Midea PC 00 means IPM malfunction or IGBT over-current protection. Switch the unit off if PC 00 shows and leave it off.

What it means
IPM malfunction or IGBT over-current protection.
Is it serious?
Yes. Midea PC 00 is a high-severity compressor fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Switch the unit off if PC 00 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the display. The manufacturer's fault list gives no homeowner fix for PC 00, so leave it for diagnosis.
Is it worth repairing?
Whether Midea PC 00 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on PC 00.Midea by age, from our Midea page:
Midea repair-or-replace guidance by system age
System ageUsual call
Under 3 yearsRepair, and check the warranty first.
3-5 yearsRepair sensor, drainage and capacitor faults.
5-7 yearsThis is the decision range.
Over 7 yearsReplace after a major component failure.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Midea PC 00 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Midea PC 00 Mean?

Midea PC 00 is listed as IPM malfunction or IGBT over-current protection in Inverter Split entries such as Midea wall-mounted inverter error-code quick troubleshooting table. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model and series before accepting a parts quote.

What Causes Midea PC 00?

Midea's fault list for Midea wall-mounted inverter error-code quick troubleshooting table gives the meaning of Midea PC 00 but not its causes. These are typical for this fault type, not listed for PC 00.

  • Compressor start, lock, overcurrent, overload, or inverter-drive protection.

  • Power-module, IPM, voltage, or wiring fault affecting compressor drive.

  • Compressor mechanical or winding issue after electrical checks are confirmed.

What Does a Technician Check for Midea PC 00?

Before quoting parts for Midea PC 00, a technician should confirm whether PC 00 is compressor start, overload, lock, or drive protection.

  • Check supply voltage, inverter output, IPM status, compressor current, and winding readings.

  • Review trip history and compressor mechanical signs before quoting replacement.

  • Detail
    Diagnostic note
    What it says
    Use the source quick-check path: Check the wiring connection, inverter module, outdoor main PCB, and compressor.
  • Detail
    Singapore / model note
    What it says
    Source is an official Midea regional wall-mounted inverter fault table; confirm the exact unit manual if the display differs on a Singapore model.

Will Midea PC 00 Need a Repair or a New Unit?

Midea PC 00 is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.

Midea PC 00 Questions

What does the Midea PC 00 error code mean?
Midea PC 00 means IPM malfunction or IGBT over-current protection, according to Midea's fault list for Midea wall-mounted inverter error-code quick troubleshooting table. The code names the fault the unit has detected, not the failed part. A technician confirms which part is at fault by measurement before quoting a repair.
Is it safe to keep running an aircon showing Midea PC 00?
Treat Midea PC 00 as a fault to diagnose, not a display to clear. Switch the unit off if PC 00 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the display.
What causes Midea PC 00?
Midea's fault list for Midea wall-mounted inverter error-code quick troubleshooting table gives the meaning of Midea PC 00 but not its causes. Typical causes for this fault type are compressor start, lock, overcurrent, overload, or inverter-drive protection; power-module, IPM, voltage, or wiring fault affecting compressor drive.
Is Midea PC 00 worth repairing?
Whether Midea PC 00 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair.
How much does it cost to find out what is causing Midea PC 00 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Midea PC 00 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.