Midea Aircon PC 04 Error Code

Midea PC 04 means inverter compressor drive error. Switch the unit off if PC 04 shows and leave it off.

What it means
Inverter compressor drive error.
Is it serious?
Yes. Midea PC 04 is a high-severity compressor fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Switch the unit off if PC 04 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the display. The manufacturer's fault list gives no homeowner fix for PC 04, so leave it for diagnosis.
Is it worth repairing?
Whether Midea PC 04 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on PC 04.Midea by age, from our Midea page:
Midea repair-or-replace guidance by system age
System ageUsual call
Under 3 yearsRepair, and check the warranty first.
3-5 yearsRepair sensor, drainage and capacitor faults.
5-7 yearsThis is the decision range.
Over 7 yearsReplace after a major component failure.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Midea PC 04 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Midea PC 04 Mean?

Midea PC 04 is listed as inverter compressor drive error in Inverter Split entries such as Midea wall-mounted inverter error-code quick troubleshooting table. This meaning comes from the manufacturer's own diagnostic material. Confirm the exact model and series before accepting a parts quote.

What Causes Midea PC 04?

Midea's fault list for Midea wall-mounted inverter error-code quick troubleshooting table gives the meaning of Midea PC 04 but not its causes. These are typical for this fault type, not listed for PC 04.

  • Compressor start, lock, overcurrent, overload, or inverter-drive protection.

  • Power-module, IPM, voltage, or wiring fault affecting compressor drive.

  • Compressor mechanical or winding issue after electrical checks are confirmed.

What Does a Technician Check for Midea PC 04?

Before quoting parts for Midea PC 04, a technician should confirm whether PC 04 is compressor start, overload, lock, or drive protection.

  • Check supply voltage, inverter output, IPM status, compressor current, and winding readings.

  • Review trip history and compressor mechanical signs before quoting replacement.

  • Detail
    Diagnostic note
    What it says
    Use the source quick-check path: Check the inverter module, outdoor main PCB, and compressor.
  • Detail
    Singapore / model note
    What it says
    Source is an official Midea regional wall-mounted inverter fault table; confirm the exact unit manual if the display differs on a Singapore model.

Will Midea PC 04 Need a Repair or a New Unit?

Midea PC 04 is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.

Midea PC 04 Questions

What does the Midea PC 04 error code mean?
Midea PC 04 means inverter compressor drive error, according to Midea's fault list for Midea wall-mounted inverter error-code quick troubleshooting table. The code names the fault the unit has detected, not the failed part. A technician confirms which part is at fault by measurement before quoting a repair.
Is it safe to keep running an aircon showing Midea PC 04?
Treat Midea PC 04 as a fault to diagnose, not a display to clear. Switch the unit off if PC 04 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the display.
What causes Midea PC 04?
Midea's fault list for Midea wall-mounted inverter error-code quick troubleshooting table gives the meaning of Midea PC 04 but not its causes. Typical causes for this fault type are compressor start, lock, overcurrent, overload, or inverter-drive protection; power-module, IPM, voltage, or wiring fault affecting compressor drive.
Is Midea PC 04 worth repairing?
Whether Midea PC 04 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair.
How much does it cost to find out what is causing Midea PC 04 in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Midea PC 04 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.