Isolator or power point: what each costs
In published Singapore rates, a 15A power point for a single unit costs least. A 20A or 32A isolator, needed for larger units, costs more, and a long run from the board moves either job up.
Snowflake prices electrical work apart from the installation. Licensed electricians do it where a job needs it.
| Electrical job | Market range in Singapore | Our rate |
|---|---|---|
| Isolator switch supplied and installed, 20A or 32A | $180–$600 per job | Quoted per job |
| 15A aircon power point, single unit | $250–$350 per job | Quoted per job |
| Cable upgrade to a larger size | No published cable-upgrade price was found; the length of the run and how it is concealed set it. | Quoted per job |
A 32A isolator and a long run from the distribution board sit at the top of the isolator range. Concealing cable in a wall costs more than running it in trunking.
Market ranges: published rates from 4 Singapore operators; published rates from 3 Singapore operators. Checked 20 Nov 2026.
What each part does
The circuit runs from the distribution board to the aircon. A small single unit can run from a 15A power point. A larger unit or a multi-split takes a 20A or 32A isolator, a switch near the unit that cuts its supply so it can be worked on safely.
The outdoor unit's rated current decides which one, and the cable size. A new system may reuse an existing circuit if its rating and cable suit the new unit.
Who is allowed to install them?
In Singapore, electrical work has to be done by a licensed electrical worker. That covers new circuits, isolators and cable upgrades, even when the aircon installer arranges the visit.
Ask the installer who does the electrical part and whether that person is licensed. The licence belongs to the worker, not to the aircon company.
What a licensed electrical worker should do
Ask for the work to be tested before the aircon is switched on.
- Check that the distribution board has a spare way and a suitable breaker.
- Size the cable and breaker to the outdoor unit's rated current.
- Fit the isolator within reach of the outdoor unit.
- Test the circuit before the aircon is connected.
- Leave the circuit labelled at the distribution board.