Gas Leak in Concealed Aircon Piping: Repair Options and Cost

A leak in piping hidden behind plaster or a ceiling board costs more to reach than to repair. Three options exist, and the right one depends on where the leak is and how much of the finish you are willing to open.

On this page

Repair, reroute or replace a concealed leak?

Repair the hidden section when the leak is in one place and the finish can be opened and patched. Reroute in exposed trunking when the run is long, the leak is hard to reach, or the finish is costly to open.

Gas leak in concealed piping: the three options

Scroll to see more columns

OptionMarket range in SingaporeOur rateWhat it involves
Leak test to place the leak$50–$180 per jobQuoted per jobPressure test and leak search along the run
Open the finish and replace the hidden section$150–$500 per jobQuoted per jobWall or ceiling opened at the leak, section replaced, finish patched
Abandon the hidden run and reroute in exposed trunkingFewer than three operators publish a reroute price; the new route's length sets it.Quoted per jobNew pipe run outside the wall in trunking; old run left in place

The patch price covers a small opening; a longer hidden section, tiles or a feature wall cost more to open and make good. Every option ends with a vacuum and a recharge by weight.

Market ranges: published rates from 4 Singapore operators; published rates from 3 Singapore operators. Checked between 18 Nov 2026 and 20 Nov 2026.

Our rates are from our rate card.

Why the leak test comes first

A concealed run cannot be inspected by eye. The leak test narrows the leak to a section before anything is opened, so only that part of the wall or ceiling comes apart.

If the test points to a joint at the indoor or outdoor unit rather than the hidden run, no wall needs opening at all.

What decides between the options

HDB keeps aircon pipes out of reinforced concrete, so concealed runs in flats sit in boxing, false ceilings or trunking.

  • Where the leak is: one point, or several along the run.
  • What hides the pipe: plaster, a false ceiling, tiles or a feature wall.
  • Whether exposed trunking is acceptable in that room.
  • Whether the room is being renovated anyway.

Avoiding a repeat

A concealed run that leaked once may leak again elsewhere along its length. If a second leak appears, rerouting or replacing the whole run is usually cheaper than opening the finish again.

Common questions

How much does it cost to fix a leak in concealed aircon piping?
Fixing a leak in concealed aircon piping is quoted as one job by Singapore operators, covering opening the wall or ceiling, replacing the hidden section and patching the finish, with the leak test priced separately. Larger openings, tiles or feature walls raise the cost.
Can concealed aircon piping be replaced with exposed trunking?
Yes. A leaking concealed aircon pipe run can be abandoned in the wall and replaced by a new run in exposed trunking. It avoids opening the finish along the old route, and suits long runs or hard-to-reach leaks, at the cost of visible trunking in the room.
How do technicians find a leak in hidden aircon pipes?
Technicians find a leak in hidden aircon pipes by pressurising the circuit: the joints at each unit are checked first, and the search narrows the leak to a section of the run. Only that section of wall or ceiling is then opened.
Can aircon pipes be embedded in an HDB wall?
Not in reinforced concrete. HDB's rules keep aircon pipes out of a flat's concrete structure, meaning its slabs, columns and beams. Concealed runs in HDB flats sit in boxing, false ceilings or trunking instead, which can be opened to reach a leak when needed.