Open the SP Group app half-hourly smart-meter chart to isolate aircon spikes at Q4 2026's 31.16 cents/kWh (incl. 9% GST) tariff. Healthy inverter aircons step down after 60 to 90 minutes, whereas flat high overnight plateaus point to choked coils, drifted thermistors, low gas, or ageing 1-tick compressors.
How Aircon Power Graphs Differ from Water Heaters and Dryers
Monthly utility totals hide which appliance drove your extra S$80 bill. If your HDB flat or condo has an AMI smart meter installed, the SP Group app displays electricity draw in 30-minute kWh bars so you can match exact clock times against bedtime habits.
Compare the visual shape of your overnight and evening bars against common Singapore household loads:
Scroll to see more columns
| SP Group 30-min bar shape | Typical kWh per 30 mins | Likely household cause | Monthly cost impact (31.16 c/kWh) |
|---|---|---|---|
| Tall initial bar, then low steady drop | 0.45 kWh falling to 0.15 to 0.25 kWh | Healthy 5-tick inverter modulating down | Normal ~S$28 to S$45 per bedroom/month |
| Flat tall plateau from 11pm to 7am | 0.65 to 1.10 kWh every half hour | Aircon stuck at full speed (dirty coil / leak / sensor) | Extra S$60 to S$130+ wasted monthly |
| Single sharp spike at shower time | 1.20 to 1.80 kWh for 1 bar only | Instant electric water heater or oven | Brief normal burst, not overnight aircon |
| Heavy 2-hour daytime block | 0.90 to 1.40 kWh across 3 to 4 bars | Heat-pump or vented clothes dryer cycle | Matches laundry days, disappears overnight |
| High baseline even when nobody is home | 0.30+ kWh steady during empty workdays | Failed fridge seal, heater left on, or rogue switch | Turn off breakers briefly to isolate circuit |
Four Aircon Faults That Trap an Inverter at Peak Wattage
Modern Singapore 4-tick and 5-tick inverters save electricity by slowing compressor speed once bedroom air reaches 25°C. When your 1am to 6am SP Group bars stay nearly as tall as your 10pm startup bar, the compressor never reaches cruise speed.
Four specific mechanical issues cause that stubborn overnight plateau. A choked indoor blower or lint-blanketed outdoor condenser blocks heat exchange so the room cools too slowly. A drifted room thermistor misreads true bedroom temperature and keeps calling for maximum cooling.
A slow R32 or R410A refrigerant leak reduces cooling capacity per cycle, forcing the compressor to spin flat-out continuously. Finally, an ageing 1-tick or non-inverter unit simply lacks low-speed modulation and pulls heavy current all night.
Run a Two-Night Comparison Test Inside the SP Group App
Before booking repairs, run a clean two-night check using identical bedtime hours. On Night 1, keep your normal 24°C or 25°C setting and note the exact time you switch off the room aircon in the morning.
On Night 2, wash the mesh filters first, set the remote to 25°C with medium fan, and run a floor or ceiling fan if available. Check the SP Group half-hourly tab the next afternoon once meter data syncs.
Subtract your empty-room 3am fridge baseline (typically 0.08 to 0.15 kWh per 30 minutes) from the active aircon bars. Multiply the total nightly aircon kWh by 30 days and S$0.3116 to calculate exact monthly running cost at Q4 2026 Singapore rates.
What to Do When Your Overnight Aircon Graph Refuses to Drop
Catching a high-wattage plateau early saves hundreds of dollars before a strained compressor fails completely. Match your graph findings to the most cost-effective next step:
- Screenshot three nights of your SP Group half-hourly chart alongside the rooms running and remote setpoint used.
- Unwashed filters or outdoor coils over six months old? Book general servicing (S$50/S$30/S$25) or outdoor cleaning (S$60 steam / S$100 pressure).
- Clean unit still pulling over 0.65 kWh per half hour overnight? Book a S$30 diagnostic check (credited on repair) to test sensors and gas charge.
- Running an old 1-tick or 2-tick unit nightly? Weigh repair costs against a 5-tick swap using NEA Climate Vouchers.