Verified LG CH22, CH29 and CH67 fault meanings
LG multi-split condensers such as the Z4UQ34GFA1 and Z3UQ28GFA1 monitor input current, inverter phase current, and condenser fan speed continuously. Whenever electrical load or fan feedback leaves safe boundaries, the controller halts cooling and flashes the matching CH code.
Although CH22 and CH29 both relate to overcurrent protection, they monitor different points in the electrical path. Meanwhile, a stalled outdoor fan behind CH67 can rapidly trigger secondary pressure and amperage faults if ignored.
| Code | Fault category | Verified LG meaning and on-site diagnostic check |
|---|---|---|
| CH22 | Compressor / Electrical Fault | CT2 error, alternating current input too high: clamp-test mains draw, inspect condenser heat dissipation, and verify refrigerant charge. |
| CH29 | Compressor / Electrical Fault | Inverter compressor amperage is too high: test compressor windings, check locked rotor condition, and verify outdoor inverter board. |
| CH67 | Fan Motor Fault | Outdoor fan error: inspect blade obstruction, shaft bearings, DC fan motor feedback signal, and outdoor PCB fan port. |
Why heat buildup on HDB ledges triggers overcurrent faults
Compact HDB aircon ledges with louver grilles restrict exhaust airflow whenever outdoor fins collect construction dust or kitchen grease. Trapped hot air forces discharge pressure higher, pushing total alternating current input into CH22 limits and inverter compressor draw into CH29 territory.
Overcharged refrigerant from an unweighed gas top-up produces the same electrical overload. Technicians verify superheat, subcooling, and clamp-meter current before declaring the compressor or control board defective.
Isolating outdoor fan motors from outdoor control boards
Keep electrical breakers untouched and never reach through condenser grilles to spin blades while power remains connected. A seized DC fan motor can overload the outdoor board's driver circuit if restarted repeatedly.
Technicians spin the fan hub manually with the isolator locked off, test motor winding pins for shorts, and check board drive voltage. Faulty fan motors are swapped directly, while any damaged outdoor PCB is replaced as a complete factory board rather than repaired.
Common questions
Can a clogged outdoor condenser cause LG CH22 or CH29 overcurrent errors?
What happens if an LG CH67 outdoor fan error is left unaddressed?
How do technicians distinguish an LG fan motor failure from a board fault?