Quick summary
Mitsubishi Heavy's Singapore terms give one year on parts and five years on the compressor alone. A covered compressor is a free part, not a free job, and the start date is not stated in the terms, so get it written on the invoice.
What the Two Warranty Periods Actually Mean
Mitsubishi Heavy publishes two periods for Singapore units: one year on parts and five years on the compressor. They cover different things.
The one-year parts warranty governs almost every fault you will meet: indoor fan motor, control board, thermistors, outdoor fan, expansion valve, drain pump. After the first year a board failure is your cost, however much compressor warranty is left on paper.
Free Compressor Does Not Mean Free Repair
When a compressor fails inside the five-year window, Mitsubishi Heavy supplies the replacement. Fitting it is separate: labour, recovering and recharging refrigerant, pulling a vacuum, replacing the filter drier, and flushing the line set if the failure was a burnout.
Two quote errors are common: one that charges for the compressor itself, and one that treats the whole job as covered. Get the quote split into parts and labour, with the compressor line at zero and the rest itemised.
A burnout sends contamination through the refrigerant lines. Flushing them is not warranty work, and it is not optional. Skipping it sets the new compressor up to fail the same way, outside warranty.
Get the failure cause written down before the old compressor leaves site. Once it is gone, nothing settles whether the failure was electrical or mechanical.
The Start Date the Terms Do Not State
Mitsubishi Heavy's published Singapore terms do not say whether the warranty clock starts at purchase or at installation. A unit bought during a renovation and installed three months later has either three months less cover than the owner assumes, or exactly as much.
Settle it at the point of purchase, not at the point of failure. Ask the dealer to state the commencement date on the invoice, and keep the installation record alongside it.
Register the unit as soon as it is installed. An unregistered unit is not automatically uncovered, but it turns a routine claim into an evidence exercise.
| What you keep | What it proves | Get it when |
|---|---|---|
| Dated purchase invoice | The unit is yours and when it was bought | At purchase, before the installer leaves |
| Commencement date in writing | Which date the warranty runs from | At purchase, from the dealer |
| Registration confirmation | Model and serial sit on the distributor record | Within days of installation |
| Servicing invoices | The unit was maintained as required | Every visit, from the first one |
Reconstructing the Record, and Units You Did Not Buy
Build the file before you need it, with the purchase invoice as the anchor. Failing that, a dated installation record, a renovation contract listing the unit, or a delivery order will usually establish when the system entered service. Photograph the indoor rating plate, and have the outdoor plate's model and serial written onto the next service report.
Second-hand and inherited units sit in a different position. Warranty terms are commonly tied to the original purchaser, so a unit that came with a resale flat may carry no transferable cover at all. Establish that before relying on it.
Servicing Is Excluded, and It Is Also a Condition
Mitsubishi Heavy states the warranty does not cover ad-hoc service. Routine servicing and chemical cleaning stay on your bill in year one and every year after.
Maintenance also sits on the other side of the ledger. Manufacturer warranties across the market treat neglect as grounds to reject a claim, and a unit with no service history is a weak claim whatever failed. Keep dated service invoices with the warranty terms.
Mitsubishi Heavy does not publish a restriction that servicing must be done by its own crew. Some other brands tie an extended term to that, so check who may touch the unit before booking anyone.
When the Warranty Stops Being the Deciding Factor
Past year one, the warranty rarely decides the repair question. A four-year-old unit with a failed fan motor is out of parts cover and inside compressor cover, so the remaining warranty is irrelevant to that fault. The decision reverts to the ordinary one: the repair cost against the unit's age and condition.
The exception is any fault that might be the compressor, where the remaining term is worth real money and worth confirming before anyone dismantles anything. A unit that trips on start, hums without turning, or runs without cooling may be a compressor, a capacitor, or a control fault, and those are separated by testing rather than by symptom.
Confirm the diagnosis before the warranty position is assumed either way. The failure mode of a warranty claim is rarely a rejection letter. It is a compressor replaced without the paperwork that would have made it free, or a capacitor replaced as a compressor because nobody tested first.
If the unit is approaching the end of year one, bring forward anything you have been ignoring: intermittent faults, a noise that comes and goes, cooling that is not quite what it was. Those are cheap to report inside the parts window and expensive to discover outside it.
Drainage Faults Can Sit Under Two Covers at Once
Watch for a drip that appears occasionally, a stain spreading on the wall below the unit, or a smell that rises when the aircon runs. Drainage faults that start small during the first year are frequently installation-related. That puts them inside both the parts warranty and the installer's own workmanship cover.