Replacing a Window Casement Unit with Single-Split

Window casement aircons house the loud compressor directly inside the bedroom frame, vibrating glass panes all night. Moving to a wall-mounted single-split pushes the condenser onto the exterior HDB ledge while cutting power waste.

On this page

Quick summary

Swapping an old window casement unit for a 5-tick single-split inverter slashes bedroom compressor noise, lowers overnight SP Group electricity draw, and qualifies eligible HDB households for S$400 Climate Vouchers. Proper replacement still demands window sealing, compliant drainage, and a dedicated 20A isolator check.

Book servicing on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

How Single-Split Inverters Cut Bedroom Noise and Power Bills

Casement units bolt the noisy compressor right beside your bed, rattling window sashes all night. Single-split systems isolate that condenser outdoors on the HDB aircon ledge.

An ageing fixed-speed casement pulling 1.0 kW through an 8-hour sleep cycle uses 8.0 kWh. That equals roughly S$75 monthly under SP Group's 31.16 cents per kWh rate (GST included). A 5-tick inverter modulating near 0.38 kW draws about 3.0 kWh nightly, or S$28 monthly.

Compare Casement Units Against 5-Tick Single-Split Upgrades

Review electrical, drainage, acoustic, and running-cost shifts before removing your window casement:

Scroll to see more columns

Compare casement units against 5-tick single-split upgrades summary table
Upgrade areaLegacy window casement5-tick single-split setupHDB compliance point
Bedroom noise profileCompressor inside window frameQuiet indoor fan; condenser outsideApproved HDB ledge placement required
Power supply pointOften plugged into 13A or 15A socketDedicated 20A double-pole isolatorLicensed LEW check if new spur needed
Condensate drainageRear drip tray or window tubeInsulated 16mm PVC to floor trapNo free dripping onto lower flats
Nightly 8h energy math~8.0 kWh fixed draw (~S$75/mo)~3.0 kWh modulated (~S$28/mo)Eligible 5-tick models fit S$400 voucher

Plan HDB Window Sealing, Drainage, and 20-Amp Wiring Prep

Removing a casement leaves a rectangular window gap that needs weatherproof aluminium composite infill and exterior silicone caulk. Larger openings may require matching glass pane glazing.

Installers must route the 16mm drain pipe discreetly into a bathroom or kitchen floor trap rather than dripping outdoors. When no 20A isolator exists, an EMA-licensed electrician runs one from the distribution board.

Check Voucher Eligibility and Book a Pre-Install Site Survey

Verify model eligibility and trunking routes before scheduling installation day:

  • Confirm your chosen single-split carries a valid 5-tick NEA listing. Eligible HDB homes can apply S$400 Climate Vouchers before late 2027.
  • Check your distribution box for a spare breaker slot. Measure how far the bathroom floor trap sits from the indoor wall mounting point.
  • Book a S$30 Snowflake on-site survey to inspect ledge access and pipe paths. That fee drops completely off your installation invoice.
  • Maintain new single-split heads cleanly afterward at published flat fees. General washes cost S$50 (14-day warranty), while chemical servicing runs S$80 (60-day warranty).

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Can an HDB owner plug a new single-split inverter into an existing 13A wall socket?
Single-split inverters in Singapore require a dedicated 20A double-pole isolator spur rather than an ordinary 13A room socket. When an existing aircon spur is missing, an EMA-licensed electrical worker must wire one safely from the distribution board.
Who patches the window opening after removing a legacy casement aircon in an HDB flat?
Aircon installers typically blank off smaller casement cut-outs using sealed aluminium composite panels and weatherproofing silicone. Larger rusted frames or matching glass panes may still require a glazier before finishing room paint.
Do single-split replacements qualify for S$400 NEA Climate Vouchers in Singapore?
Eligible HDB households upgrading to registered 5-tick single-split inverters may redeem S$400 Climate Vouchers at participating retailers through late 2027. Check the NEA product portal beforehand so the exact indoor and outdoor model pairing qualifies.
Where must condensate water drain after phasing out a bedroom casement aircon?
HDB installation rules require piping indoor condensate water directly into an internal bathroom or kitchen floor trap. Venting drain tubes out windows violates nuisance rules and risks fines if water drips onto lower laundry racks.