Quick summary
Alkaff BTO blocks and Sennett condos around Potong Pasir often hide aircon blowers inside recessed ceiling pelmets or above full-height wardrobes. Coordinating trip 1 copper piping, drainage slope, and minimum top intake spacing prevents cold air short-cycling and cabinet sweating.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Coordinate Trip 1 Piping Before Wardrobe and Pelmet Boxing
Alkaff BTO flats and Sennett condos frequently route aircon pipes behind plasterboard bulkheads and full-height wardrobes. Completing trip 1 piping early gives carpenters exact beam clearances before fabricating laminated cabinets. Early coordination avoids costly hacking after wardrobes arrive.
Always specify 22 SWG copper lines wrapped inside tight half-inch Class 0 Armaflex insulation. Log disconnected nitrogen pressure photos and verify smooth water drain flow before wet trades close ceiling voids. Request a clear as-built trunking sketch from the installer. Store those timestamped pressure records safely until final handover.
Compare Potong Pasir BTO and Condo Installation Rules
HDB estates around Alkaff and private developments near Potong Pasir MRT follow distinct handover requirements. Review permit timelines and carpentry clearances side by side before work starts:
Scroll to see more columns
| Project factor | Alkaff & Potong Pasir BTO | Sennett & nearby condo | Carpentry & airflow rule |
|---|---|---|---|
| Permit & sign-off | BCA-trained team files Form AC-02 | MCST permit, deposit, lift padding | Confirm piping path before joinery fabrication |
| Pelmet spacing | Keep 10-15 cm above indoor unit | Clear deep curtain bulkhead lips | Avoid trapping cold exhaust inside cove |
| Drain routing | Continuous drop to bath floor trap | Glued PVC slope before box-up | Avoid dipping drains across wardrobe tops |
| Grant or tick target | S$400 HDB Climate Vouchers (5-tick) | Quiet 5-tick multi-split sizing | Match outdoor chassis to ledge louvers |
Prevent Recessed Pelmet Short-Cycling and Wall Sweating
Recessing an indoor blower deep inside a tight plaster pelmet bounces cold air straight into top intake sensors. Compressors cycle off early while rooms feel humid. Damp mist also condenses across nearby wood veneer.
Keep 10 to 15 cm of clear top intake space above every indoor casing. Align discharge louvres flush with curtain recess edges so cool air sweeps across the room cleanly. HDB owners must also have BCA-trained installers lodge Form AC-02 within 14 days without cutting beams. Sennett condo owners need MCST permit sign-off and lift padding before work begins.
Plan Site Survey Costs and Post-Renovation Servicing
Coordinate carpentry clearances early and wash away fine construction dust using Snowflake's flat-rate servicing tiers:
- Schedule a S$30 site check (S$80 VRV) alongside your interior designer before joinery measurements lock. Install or repair work offsets that fee with 30-day repair cover.
- Wash away fine renovation plaster dust on three blowers at S$25 per coil, two blowers at S$30 apiece, or one coil at S$50 (14-day warranty).
- Eliminate lingering cabinet-glue smells using chemical servicing: S$60 apiece on three-plus coils, S$70 per coil for pairs, or S$80 on a standalone unit (60-day warranty).
- Heavy post-move-in biofilm calls for stripped overhauls: S$115 apiece for three-plus units, S$125 per pair, or S$150 for one FCU (90-day warranty).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

York · Cassette
Office outdoor unit failed: indoor side still had years left
A seized, salt-corroded outdoor unit above an indoor side with years of life left

Fujitsu · Cassette
Office cassette dripping at louver: sweating from fouled coil
Surface condensation on the supply louver driven by restricted airflow across one fouled coil face
Common Questions
How much clearance does an aircon need inside a BTO curtain pelmet?
Should trip 1 aircon piping happen before bedroom wardrobes are measured?
Can Alkaff BTO owners redeem HDB Climate Vouchers during aircon installation?
What approvals do Sennett and Potong Pasir condo owners need before replacement?