Disclosing aircon compressor age and recording a cool-mode test at Option to Purchase (OTP) exercise protects resale HDB sellers from completion-day repair arguments. Dated intake and outlet readings, tidy servicing receipts, and a clean drain inspection prove units worked honestly through vacant possession.
Wall-mounted general servicing $25–$50/unit · chemical wash $60–$80/unit · View servicing rates
Disclose Aircon Age Clearly Before Signing the Resale Option
HDB Option clauses require fixed appliances to remain in the same working state seen at buyer viewings. Buyers inspecting an eight-year-old split rarely expect brand-new cooling output, provided sellers disclose age openly.
Silent omissions spark friction near completion day. Record installation year, brand model, and working blower count on your inventory sheet before Option exercise.
Note sluggish louver motors, missing remote controllers, or yellowed plastic casings in writing. Honest baseline records stop buyers from demanding late-stage compressor swaps.
Record Working Status from Option Stage to Key Completion
Keep timestamped handover proof across both initial viewings and vacant-possession walkthroughs using safe indoor checks:
Scroll to see more columns
| Resale stage | Evidence sellers record | Safe HDB inspection limit | Immediate remedy needed |
|---|---|---|---|
| Pre-OTP listing | Brand, unit count, and install year | Check invoices indoors, never climb out | Note cosmetic yellow casing upfront |
| OTP exercise test | Ten-minute cool run at 18 degrees | Film indoor grille and dry floor trap | Clear clogged filters immediately |
| Pre-completion week | Recent cleaning receipt and dry walls | Follow MOM and BCA ledge rules | Service sour coils before inspection |
| Key handover day | Both parties verify cold airflow | Keep 230V breaker box covers shut | Check warm vents with S$30 diagnosis |
Run Safe Indoor Cool Tests Without Climbing on Ledges
Sellers and buyers must never step onto external HDB aircon ledges to photograph compressor labels. Keep live electrical isolator boxes closed throughout walkthrough inspections.
Verify manufacture years indoors using past contractor invoices or warranty cards. Switch all blowers to cool mode at top fan speed for ten minutes during final buyer checks.
Filming smooth swing louvers, cold vent airflow, and dry trunking walls on a dated clip creates clear vacant-possession proof before handing over flat keys.
Prepare Pre-Completion Servicing to Prevent Handover Claims
Fresh contractor receipts settle airflow or odour doubts quickly right before buyer final inspection:
- Warm vents appearing between Option exercise and completion warrant a S$30 diagnostic visit. Snowflake cancels that fee upon repair with a 30-day warranty.
- Single-room flats clean up affordably at S$50 general, S$80 chemical, or S$150 complete coil teardown.
- Two-unit setups lower per-blower bills to S$30 general, S$70 chemical, and S$125 complete overhaul per room.
- Three-plus units settle at S$25 per room for basic cleans, S$60 per room for chemical washes, and S$115 per room for full teardowns (backed by 14-day, 60-day, and 90-day warranties).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

LG · Wall-mounted
Told a near-new unit needed a chemical wash: routine clean enough
Ordinary dust on the filters and a light haze on the fin face, both clearing with a routine service

Panasonic · Multi-split
New multi-split acting strangely: swapped signal wires
Two indoor-to-outdoor signal pairs connected to each other's terminals at the outdoor unit
Common Questions
Must resale HDB sellers replace an eight-year-old aircon before completion handover?
How can sellers verify aircon working condition without climbing onto HDB ledges?
What paperwork helps resale HDB sellers prove fair aircon care before completion?
Should a seller service sour or dripping aircons before buyer inspection?