Likely causes
- Mould on the blower wheel is flung out as specks every time the fan spins.
- Growth on the coil and in the drain tray sheds flakes and smells musty.
- A humid room keeps the unit damp, so mould returns soon after a clean.

1. Mould on the blower wheel
The blower wheel sits behind the louvre and stays damp from the coil above it. Mould grows along its blades, and the spinning wheel throws flakes straight out of the outlet. The specks land on the louvre, the wall and whatever sits below.
How to tell
Specks thrown across the room point to the wheel, not the coil. The wheel is the only part that spins, so it is the part that scatters flakes.
- Black specks collect on the louvre, the wall or bedding under the unit.
- Black spots show on the fan blades when a torch is shone into the outlet.
- The filter looks clean, but the specks keep coming.
How we confirm it
A technician lights the wheel and coil to see how far the growth goes. Light growth comes off in a chemical wash on the wall. Growth packed along the blades needs an overhaul, with the wheel taken out and washed.
A filter clean misses the wheel, so specks that return straight after one were never removed.
2. Growth on the coil and drain tray
Dust on the coil holds water, and mould grows on that damp film. It shows as a dark layer behind the filter and as slime in the drain tray. Flakes from it reach the fan and the room, with a musty smell alongside.
How to tell
Smell is the tell. Specks with a musty smell and a dark coil point to growth through the unit, rather than the wheel alone.
- A musty smell comes with the specks, strongest at start-up.
- A dark film shows on the coil fins behind the filter.
- The unit has gone a long time since its last chemical wash, or never had one.
How we confirm it
A technician checks the coil, tray and wheel together, because growth rarely stops at one. A chemical wash clears the coil and tray, and the drain is flushed so the tray empties fully.
A filter clean or a spray on the coil face is not enough. Growth between the fins and in the tray survives it.
Related cases
3. A humid room feeding regrowth
Mould needs damp, and a room that stays humid keeps the inside of the unit wet. Long runs on a low fan, or switching off straight after cooling, leave the coil and wheel damp between runs. Growth then returns soon after a clean.
How to tell
Return speed separates it. Mould back soon after a full clean points to the room keeping the unit wet, instead of growth a clean missed.
- Specks return soon after a full chemical wash.
- Mould also shows on walls, ceilings or wardrobes in the same room.
- Windows stay shut and the room feels damp with the aircon off.
How we confirm it
A technician confirms the last clean went right through the unit. The unit's size for the room and its settings are then checked for whatever leaves it wet. The fix is drying the room and the unit, not washing more often.
Booking washes more often without fixing the damp misses the source, and the mould comes back each time.