Why Is My Aircon Leaking Water Right After Servicing?

A leak that starts after a service visit is usually a reassembly fault, not a failed part. Where the water appears tells a loose drain connection, a capped line, open insulation and a misplaced pan apart. Switch the unit off if water is backing up inside the casing.

On this page

Summary

Likely Causes

  • A drain connection disturbed during the visit sits loose and weeps at that point.
  • A capped or obstructed drain line backs water up until it overflows.
  • Insulation left open forms condensation outside the drain path.
  • A drain pan reseated out of position lets water bypass it entirely.
Wall unit on the wall with its front casing removed
A wall unit with its front casing removed for a wash. A drain connection pushed back short of its seat sends water past the tray.

Quick Fault Summary

  • Likely cause
    Drain connection not fully reseated
    What to check
    Drip is slow but steady, always at the same spot.
    Typical next step
    A technician traces the drip to the joint, reseats or re-angles it, then confirms it stays dry while the drain carries water.
  • Likely cause
    Drain line left capped or obstructed
    What to check
    Water backs up and spills rather than dripping steadily.
    Typical next step
    A technician locates the restriction, removes the cap or clears the obstruction, then runs a sustained cooling test to confirm the tray drains faster than it fills.
  • Likely cause
    Insulation or panel left open
    What to check
    Water shows along the trunking, not at the unit casing.
    Typical next step
    A technician opens the trunking run, finds the exposed cold section, then re-insulates and reseals it.
  • Likely cause
    Drain pan not reseated on its rails
    What to check
    Water runs down the face of the coil and drips off the bottom edge.
    Typical next step
    A technician removes and reseats the pan squarely on its guide rails, then runs the unit under cooling load and watches the water land on the pan.

1. Drain Connection Not Fully Reseated

A hose clip or fitting disturbed during the visit and not fully seated weeps at one fixed point. Most water still clears, so the leak starts days later.

How to Tell

Unlike an overflow, the tray does not fill. The drip sits at the unit instead of tracking along the trunking.

  • Drip is slow but steady, always at the same spot.
  • Cooling feels exactly the same as before the visit.
  • The leak started days after the visit, not that evening.
  • The flat had no history of leaking before.

How We Confirm It

A technician traces the drip to the joint, reseats or re-angles it, then confirms it stays dry while the drain carries water. Send a photo of where the water appears with the WhatsApp message.

A leak near a condensate pump is not automatically a pump fault. Replacing the pump does not fix a loose fitting, and the leak returns on the new part.

Related Cases

2. Drain Line Left Capped or Obstructed

Pooling, spilling water points to a closed drain: a cap left on the outlet, or debris knocked into the line during the visit.

How to Tell

The overflow rises the longer the unit runs. Unlike open insulation, the water comes from the front of the indoor unit, not along the trunking.

  • Water backs up and spills rather than dripping steadily.
  • It gets worse the longer the unit stays on.
  • Switching the unit off stops the water building.
  • Gurgling near the indoor unit before the overflow starts.

How We Confirm It

A technician locates the restriction, removes the cap or clears the obstruction, then runs a sustained cooling test to confirm the tray drains faster than it fills.

Do not keep running the unit while water is backing up. Overflow inside the casing reaches the control board, which turns a blocked drain into an electrical fault.

Related Cases

3. Insulation or Panel Left Open

Water along HDB or condo trunking is humid-air condensation outside the drain path. Insulation opened during servicing leaves cold copper bare while the drain clears normally.

How to Tell

Flushing changes nothing, and the water tracks with humidity rather than with how long the unit has run.

  • Water shows along the trunking, not at the unit casing.
  • Worse on humid days and after rain.
  • Nothing spills from the front of the indoor unit.
  • Flushing the drain makes no difference to the leak.

How We Confirm It

A technician opens the trunking run, finds the exposed cold section, then re-insulates and reseals it. A run through humid weather confirms the sweating has stopped.

Repeated drain flushing will not fix this leak, because the water never enters the drain. If one flush has already changed nothing, the trunking route needs opening instead.

Related Cases

4. Drain Pan Not Reseated on Its Rails

The pan was lifted out for cleaning and sits a few millimetres out of its guide rails, so condensate falls past it.

How to Tell

Water misses the drain completely, so testing the line always shows it clear. The drip starts immediately rather than days later.

  • Water runs down the face of the coil and drips off the bottom edge.
  • It appears immediately, not days later.
  • Water falls straight down from under the unit rather than along the pipe.
  • The last visit was a deep clean rather than a filter wash.

How We Confirm It

A technician removes and reseats the pan squarely on its guide rails, then runs the unit under cooling load and watches the water land on the pan.

Clearing the drain does not fix a pan that is out of position.