Why Does My Aircon Smell Like Sewage or Rotten Eggs?

Three things make an aircon smell of sewage: drain air in the water pipe, stagnant tray water, or a dead pest. How suddenly the smell started and when it peaks tell them apart.

Safety warning. A rotten-egg smell near a gas cooker or water heater points to piped gas if it stays with the aircon off. Leave the area and contact the gas supplier.

On this page

Likely causes

  • A dry drain trap or an unsealed drain joint lets drain air back up the water pipe.
  • Water left standing in the drain tray turns stagnant and smells sour or rotten.
  • A dead lizard or other pest in the casing or drain gives a rotting smell that starts suddenly.
Drain tray with rust and standing water
A drain tray holding stagnant, rust-coloured water. Water that sits in the tray between runs turns sour, and the fan carries the smell out at start-up.

1. Drain air coming back up the water pipe

The aircon's water pipe ends at a floor trap or a building drain. Water sitting in the trap seals drain air out. A trap left dry, or a joint never sealed, lets that air back into the unit and the room.

How to tell

Unlike tray water, this smell needs no dirt in the unit. A clean unit with a working drain that still smells of sewage points to the drain connection.

  • The smell is sharp and sewage-like, not musty.
  • It started after a new installation, a renovation or a long spell with the unit off.
  • The unit looks clean and the drain still empties normally.

How we confirm it

A technician traces where the water pipe discharges, then checks the trap for water and the joint for a seal. A dry trap is refilled or an open joint sealed. The smell is rechecked with the unit running.

A chemical servicing will not fix a smell from the drain, so the drain connection is checked first.

Related cases

2. Stagnant water in the drain tray

Water that cannot drain fully sits in the tray between runs. Sludge and bacteria turn it sour, and the fan pushes the smell out when the unit starts. A part-blocked outlet or a tray that has lost its fall leaves this standing water.

How to tell

Timing separates it. A sour smell that peaks at start-up with slow drainage points to the tray. Drain air, in contrast, smells however well the drain flows.

  • The smell is strongest in the first minutes after switching on.
  • It is worse after the unit has been off for a few days.
  • Occasional drips or a gurgle from the indoor unit come with it.

How we confirm it

A technician checks for standing water in the tray, clears the outlet and flushes the drain line. The drain is then tested to confirm the tray empties fully.

Fragrance sprays and tablets cover the smell, but the standing water stays and the smell comes back.

Related cases

3. Dead pest in the casing or drain

Lizards, cockroaches and rodents get in through gaps around the wall pipe hole or up the drain line. One that dies inside gives a strong rotting smell. It builds over a few days, then fades slowly as the remains dry out.

How to tell

Sudden onset marks a pest, whereas tray water and drain air build or come and go. A rotting smell that appeared overnight and keeps strengthening points to something dead inside, not a drain fault.

  • The smell arrived suddenly on a unit that smelled fine before.
  • It is a heavy, rotting smell that grows stronger over a few days.
  • Lizards, cockroaches or ants have been seen near the unit or its pipe hole.

How we confirm it

A technician opens the casing, finds and removes the remains, and cleans the tray, fan and coil they touched. Gaps around the pipe hole are sealed so the next pest has no way in.

Do not spray insecticide or fragrance into the unit. The chemical coats the coil and fan, and the remains are still inside.