How do you cool a room without a window?
A split system works when its pipes can reach an outdoor unit position within the manufacturer's limits, and its drain can fall all the way out. A ducted branch works when a nearby ceiling has room for the unit and its duct.
A portable needs an opening for its hose, which an internal room does not have. For a store room used for minutes at a time, going without aircon is a fair answer too.
| Option | Works when | Ruled out by |
|---|---|---|
| Wall split with a longer pipe run | The run to the ledge stays inside the outdoor unit's length and height limits | A drain that has to rise, or no permitted outdoor position |
| Ducted branch from a nearby ceiling | The ceiling void fits the unit, an inspection opening and the duct | No ceiling depth, or a duct that exceeds the fan's static pressure range |
| Portable unit | A window or opening sits within reach of the supplied hose | No opening at all, since the hose cannot be lengthened |
| No aircon | The room is a store used briefly | A study or bedroom used for hours at a stretch |
What limits a split's pipe run to the ledge?
The outdoor unit's installation manual sets the limit, and each model has its own figures. Daikin's European guide for its 3MXM multi-split units allows up to 25 m of piping to each room and 50 m in total, with at least 3 m per room.
Height counts as well: up to 15 m between the units when the outdoor unit sits higher, and 7.5 m when it sits lower. Shorter piping performs better, and a longer run can need extra refrigerant; see maximum pipe length.
The drain is often the harder limit. Daikin's wall-unit manual requires the drain hose to slope downward, and marks a hose that rises or forms waves as wrong. A room deep inside the flat can run out of fall first.
A run through a ceiling becomes concealed piping, which changes later repairs.
Where can the outdoor unit go in an HDB flat or condo?
BCA does not specify where an aircon unit must be installed. A unit outside or projecting from the building must sit on a stainless-steel bracket or a concrete ledge or casing.
Only a trained installer registered with BCA may fit such a unit, and the installer submits a report within 14 days of completion. HDB holds the flat owner responsible for the installation's safety and stability.
For an internal room, the usual route is piping back to the flat's existing ledge rather than adding a new bracket. Check that ledge for the HDB aircon ledge problems that affect a condenser, and on a condo, whether it is a common property ledge.
When a ducted branch or a portable is the better fit
A ducted unit hangs in a ceiling void and sends air to the room through a duct. Daikin's FDXM manual asks for an inspection opening and warns against exceeding the fan's external static pressure range, which a long or bent duct uses up. The concealed ducted aircon guide covers ceiling depth.
A portable sends its heat out through an exhaust hose. De'Longhi does not allow its hose to be extended, because cooling falls sharply and the unit can overheat. With no window, the heat has nowhere to go; the trade-offs are in portable aircon vs split system.
Efficiency lags too. The 29 portable registrations on NEA's register carry one or two ticks, while every registered single split carries four or five.