Quick summary
Overnight 30-minute smart meter blocks in the SP Group app show when an inverter compressor fails to throttle down. Flat 0.50 to 0.90 kWh bars past 1 am indicate full-load lockup, choked coils, or drifted sensors.
On-site fault check: $30 ($80 VRV), waived if you proceed with repair · See diagnosis & repair
Read Overnight Smart Meter Blocks in the SP Group App
Open the SP Group app consumption tab after 9 am. Switch the chart view to 30-minute intervals between midnight and 6 am. Most Singapore flats run only a fridge and bedroom aircon overnight. Background load stays near 0.08 kWh per slot.
Healthy 9,000 BTU bedrooms pull 0.35 to 0.55 kWh across the first hour at 25 degrees. Usage then tapers toward 0.14 to 0.25 kWh per half hour. Sustained bars past 0.55 kWh show the outdoor compressor stuck near top speed.
Compare Pass and Fail Readings Using Safe Indoor Checks
EMA, HDB, and MOM rules limit homeowner checks to floor level indoors. Never open 230V electrical covers, touch isolators, or climb onto exterior aircon ledges.
Scroll to see more columns
| Self-check item | Floor-level observation | Pass threshold | Fail action (S$30 check) |
|---|---|---|---|
| 01:00 to 05:00 interval bar | View single-bedroom overnight curve | Drops under 0.28 kWh per slot | Flat 0.50+ kWh bar needs S$30 check |
| Washable mesh screens | Unclip indoor front flap safely | Clean fins, steady cold airflow | Rinse dust; re-test next night chart |
| Compressor cycling sound | Listen from inside closed window | Quiet steady hum after 45 minutes | Loud clack every 4 minutes fails check |
| Room setpoint holding | Verify remote at 25 degrees cool | Room feels dry and stable | Warm air despite spike needs S$30 check |
Spot Why Inverter Compressors Lock at High Power
Dust-choked blower wheels and starved outdoor airflow force inverters to run at maximum pressure. Drifted room thermistors also trick the PCB into demanding non-stop cooling past 25 degrees.
SP Group bills regulated power at 31.16 cents each kWh (GST included) in late 2026. Wasting 0.35 kWh every half hour across eight sleeping hours burns S$1.75 nightly. That extra draw adds roughly S$52 monthly per room.
Schedule Diagnostic Checks Before Your Next Utility Bill
Act promptly once clean indoor filters fail to flatten overnight chart bars:
- Schedule a S$30 troubleshooting check (S$80 for VRV systems). Snowflake waives that visit fee when repairs proceed under a 30-day warranty.
- Light coil dust clears through general cleaning. Single units cost S$50, pairs cost S$60 combined, and three upward run S$25 each. Two-week workmanship protection applies.
- Stubborn blower grime requires chemical servicing. Pricing sits at S$80 (one), S$70 each (two), or S$60 each (three upward) with 60-day cover.
- Heavy blockages call for stripped chemical overhauls at S$150 (one), S$125 per coil (two), or S$115 per coil (three upward) under 90-day cover.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Wall-mounted
Daikin J6 outdoor red LED: bad thermistor, not condenser
Open-circuit Daikin outdoor heat-exchanger thermistor halting multi-split cooling via outdoor safety protection while the inverter compressor stays healthy

Mitsubishi Electric · Wall-mounted
Starmex stops every 15 minutes: drifted thermistor, not PCB
Drifted indoor coil pipe thermistor feeding false near-freezing readings to the Starmex PCB, triggering premature cooling cutoffs at 28°C
Common Questions
What overnight kWh number in the SP Group app flags an aircon spike?
Can dirty indoor filters cause a half-hour kWh power spike overnight?
Is every smart meter household able to view 30-minute SP Group intervals?
Why should homeowners avoid inspecting outdoor units when diagnosing high draw?
Sources
Sources checked 27 Nov 2026