Quick summary
Uneven left-to-right jet pressure across a wall vent reveals lint-matted blower blades early. Residents can hold light paper strips near intakes and outlets from floor tiles safely. Dead air bands failing a dry filter retest warrant a S$30 diagnostic check.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Stay at Floor Level Under EMA, HDB, and MOM Safety Limits
EMA electrical safety rules, HDB home guides, and MOM/BCA circulars set one clear boundary. Inspect strictly from floor tiles or a steady indoor step. Never climb onto outdoor aircon ledges or undo any 230V PCB cover.
Keep fingers, pens, and wooden rulers outside spinning fan gaps. Hold a light tissue or narrow paper strip 10 centimetres beneath the grille to test jet pressure safely.
Score Intake vs Outlet Pressure on a Pass or Fail Check
Run cool mode at 22 degrees on top fan speed for five minutes. Then sweep one dry paper strip left to right across the unit:
Scroll to see more columns
| Floor-level airflow check | Pass outcome | Fail sign | Next decision step |
|---|---|---|---|
| Top intake pull with strip | Paper clings flat above grille | Weak pull or fluttering gap | Rinse mesh screens; retest once dry |
| Left-centre-right outlet sweep | Brisk even blow across full span | Noticeable dead band on one third | Fail: book S$30 diagnosis |
| Post-filter-wash 2m throw feel | Crisp cool stream reaches bed edge | Warm pockets or pulsing gusts | Fail: book S$30 airflow check |
| Air noise along grille slot | Steady smooth whoosh from fan | Wind-tunnel roar with low breeze | Fail: needs S$30 coil inspection |
Read What Uneven Left-to-Right Grille Pressure Means
Strong top intake pull paired with a dead zone along one third of the outlet reveals blocked fan vanes. Damp lint and slimy mould pack inside specific pockets of the cross-flow barrel. Partial fin icing also stalls airflow locally.
Loud rushing air with short room throw shows the motor spins against resistance. Refrigerant refills cannot open clogged fan cups. Direct blade and coil flushing restores steady breeze.
Decide When Clean Filters Fail and Book S$30 Diagnosis
Simple mesh rinsing fixes top suction clogs within minutes. Uneven outlet fail signs call for trained indoor servicing:
- Book a S$30 diagnostic check whenever dead outlet bands stay after dry filters return. Fees waive upon repair (S$80 on VRV), carrying 30-day warranty.
- Protect open fan vanes quarterly through routine general servicing. Single splits cost S$50, two splits run S$30 each, and bundling three upward costs S$25 per split (14-day cover).
- Loosen packed fin grime through chemical servicing. One head bills S$80, two heads bill S$70 each, and three or more settle at S$60 per head (60-day warranty).
- Remove thick lint cakes from buried blower drums via dismantled overhauls. Teardown pricing sits at S$150 for a single head, S$125 per head for two, and S$115 per unit across three upward (90-day cover).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Wall-mounted
Ice forming on the copper pipe: airflow blocked, not gas
Airflow restriction from blower wheel and coil buildup, freezing the coil

Mitsubishi Electric · Wall-mounted
Warm air with normal gas pressure: fouled coil, not low gas
Grease-choked indoor evaporator coil and dust-packed blower wheel causing poor temperature drop while refrigerant pressure stayed full
Common Questions
Why does an aircon blow strongly on one side of the vent and weakly on the other?
Does a weak paper-strip test always mean the aircon is leaking refrigerant?
How far should residents hold a paper strip when testing indoor airflow safely?
When should a Singapore resident stop checking and book a S$30 technician visit?
Sources