On this page
Quick summary
GREE GWC12ATDXE-K6DNA3A/O delivers 3.47 kW output with 5 NEA green ticks under certificate ELS-SGR-AC230031, achieving 5.83 weighted COP and 1,285 kWh annual draw. That lab benchmark runs S$400 per year across current Q4 2026 electricity charges, making certificate expiry checks vital.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check GWC12ATDXE-K6DNA3A/O Output and SP Group Bills
NEA listing ELS-SGR-AC230031 certifies GREE GWC12ATDXE-K6DNA3A/O at 5 ticks and 3.47 kW output. Rated numbers show 4.99 full-load COP, 6.39 part-load COP, and 5.83 weighted COP. That places this model firmly in Singapore's 12,000 BTU single-split tier. Extra cooling reserve pulls down peak afternoon heat quickly in glazed master rooms.
Annual lab usage reaches 1,285 kWh, producing a S$347 NEA energy-label baseline. Calculated with Q4 2026 SP Group charges (31.16 cents a kWh, inclusive of GST), yearly lab consumption equals S$400. That works out near S$33 monthly. Raising thermostat targets from 22 to 25 degrees trims real household bills noticeably.
Compare GWC12ATDXE-K6DNA3A/O Test Specs and Expiry
Inspect published NEA lab test metrics alongside current power pricing and registration dates:
Scroll to see more columns
| Evaluation metric | Verified NEA value | Late 2026 Singapore figure | Sizing implication |
|---|---|---|---|
| Cooling capacity | 3.47 kW single split | 5 ticks (ELS-SGR-AC230031) | Covers 15 to 22 sqm spaces |
| Weighted efficiency | 4.99 full / 6.39 part COP | 5.83 weighted COP | Handles afternoon heat sustainably |
| Energy benchmark | 1,285 kWh annual test | S$347 NEA / S$400 Q4 2026 SP | Around S$33 monthly test average |
| Listing expiry | Expires 27 November 2026 | Verify live NEA renewal | Confirm status before voucher use |
Size 3.47 kW Cooling and Verify Active Voucher Status
Reserve 3.47 kW units for sunny master bedrooms, bedroom-study combinations, or compact condo halls where 2.65 kW splits strain against afternoon glass glare. Avoid oversizing tiny helper rooms. Excess capacity forces short compressor cycles that leave indoor air clammy. Pair west-facing curtains with balanced fan speeds so air reaches far walls.
Registration ELS-SGR-AC230031 expires on 27 November 2026. Buyers aiming to apply S$400 HDB Climate Vouchers (valid until December 2027) must check NEA's live database first. Confirm supplier renewal before paying deposits. Retailers cannot process government voucher claims on lapsed certificate listings.
Verify Listing Status and Book Routine Gree Upkeep
Confirm active certificate dates, verify room load, and plan routine maintenance under published Snowflake fees:
- Search ELS-SGR-AC230031 on NEA's public register before paying deposits. Confirm active renewal past 27 November 2026 if redeeming HDB vouchers.
- Arrange a S$30 sizing assessment—credited when installation proceeds—to verify glass exposure, drain pitch, and wall space.
- Protect efficiency with 14-day backed general upkeep: S$50 for a single bedroom unit, S$30 per blower when cleaning two rooms, or S$25 per blower on three-room packages.
- Treat coil buildup through chemical rinsing carrying 60-day cover: one coil costs S$80, two coils run S$70 each, and three or more settle at S$60 per coil. Heavy wheel grime calls for 90-day backed overhauls at S$150 once-off, S$125 in twos, or S$115 per coil on larger plans.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Wall-mounted
Tripping a 20A breaker: weak capacitor, not compressor
Degraded outdoor run capacitor combined with a dust-choked condenser coil climbing amp draw past the 20A breaker limit after 15 minutes while the compressor remains sound

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal