Gree 6.3 kW 5-Tick Multi Split kWh and Ownership Guide

Registered under MELS-SGR-AC220014, GREE GWCD(21)NK6AO pairs 6.3 kW multi-split output with 5.56 weighted COP and 2,459 kWh annual NEA test consumption. Review SP Group operating costs, room sizing limits, and flat-rate upkeep below.

On this page

Quick summary

GREE GWCD(21)NK6AO carries NEA 5-tick certificate MELS-SGR-AC220014 through December 2027 at 6.3 kW cooling capacity, 5.56 weighted COP, and 2,459 kWh yearly test use. Verified part-load efficiency of 6.01 COP keeps overnight HDB and compact condo bills predictable under current SP Group rates.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Verify Gree 6.3 kW Efficiency and SP Group Annual Cost

NEA registration MELS-SGR-AC220014 runs until 1 December 2027, certifying GREE GWCD(21)NK6AO at five ticks for multi-split duty. That outdoor compressor delivers 6.3 kW total cooling output at 4.88 full-load COP, 6.01 part-load COP, and 5.56 weighted COP.

Official NEA test consumption stands at 2,459 kWh per year, printed on the green label as S$664 annually. Applying SP Group's Q4 2026 regulated rate of 31.16 cents/kWh (including GST) translates that annual test usage to S$766, or about S$64 monthly.

Strong 6.01 part-load efficiency keeps overnight bedroom power draw modest once spaces settle around 25 degrees. Eligible HDB households also cut upfront purchase outlay using S$400 Climate Vouchers running until end-2027.

Review Gree 6.3 kW Metrics and HDB Room Sizing

Inspect official MELS registration numbers alongside practical bedroom limits before selecting your indoor coil combination:

Scroll to see more columns

Review Gree 6.3 kW metrics and HDB room sizing summary table
Verification itemOfficial GREE benchmarkSingapore flat impactPractical decision check
NEA certificateMELS-SGR-AC220014 (5 ticks)Valid until 1 December 2027Qualifies for S$400 HDB vouchers
Cooling & COP scores6.3 kW | 5.56 weighted COP4.88 full-load; 6.01 part-loadStrong overnight single-room savings
Annual test electricity2,459 kWh | S$664 label figureS$766 yearly on Q4 SP Group rateRoughly S$64 monthly average draw
Multi-room capacity6.3 kW (~21,500 BTU total)Fits two or three modest bedroomsAvoid overloading hot west halls

Match Gree 6.3 kW Capacity to Sunlit Rooms

Rated output of 6.3 kW corresponds to roughly 21,500 BTU divided across connected indoor fan coils. Two or three compact HDB bedrooms run comfortably overnight without choking blower airflow.

Open living halls exceeding 250 square feet or bedrooms facing strong west afternoon sun drive compressor draw toward 4.88 full-load COP. Specifying 22 SWG copper and half-inch insulation guards against sweating trunking.

Confirm copper pipe length and ledge clearance during a S$30 pre-install survey, which Snowflake waives completely when installation proceeds.

Schedule Routine Servicing to Protect Five-Tick Efficiency

Dust-matted evaporator fins force inverter compressors to draw extra power and sacrifice part-load COP savings. Keep your flat on predictable fixed pricing:

  • Quarterly general cleaning protects steady airflow at S$50 for one bedroom, S$30 apiece for two bedrooms, or S$25 apiece across three-plus bedrooms with 14-day workmanship protection.
  • Stubborn kitchen grease or stale odours lift during chemical servicing billing S$80 for a lone unit, S$70 per unit in pairs, or S$60 each when servicing three or more rooms under 60-day cover.
  • Heavy drain pan slime demands full dismantled chemical overhauls costing S$150 for one head, S$125 each for two heads, or S$115 per head for multi-room flats with a 90-day warranty.
  • Sudden sensor codes or weak cool airflow warrant a S$30 on-site fault check, waived whenever approved repairs proceed under a 30-day warranty.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

How much does GREE GWCD(21)NK6AO cost to run per year on Singapore electricity rates?
NEA tests log 2,459 kWh yearly for GREE GWCD(21)NK6AO, printed as S$664 on the green label. Pricing those same 2,459 kWh using SP Group's Q4 2026 rate of 31.16 cents/kWh (with GST included) yields roughly S$766 annually, or S$64 monthly.
Can HDB homeowners use Climate Vouchers on GREE GWCD(21)NK6AO?
Eligible Singapore HDB households can apply S$400 NEA Climate Vouchers toward GREE GWCD(21)NK6AO until December 2027 because it holds active 5-tick registration MELS-SGR-AC220014. Retailers verify flat address eligibility before deducting the voucher.
How many bedrooms can the 6.3 kW GREE GWCD(21)NK6AO cool comfortably?
With 6.3 kW total capacity, GREE GWCD(21)NK6AO suits two or three standard HDB bedrooms cooling overnight around 25 degrees. Pairing oversized sunlit halls with three bedrooms simultaneously strains output and lowers part-load efficiency.
What servicing interval preserves GREE GWCD(21)NK6AO's 5.56 weighted COP?
Scheduling quarterly general washes at S$25 apiece on three-blower flats keeps evaporator fins clear so draw stays near 6.01 part-load COP. Persistent grime or musty smells call for chemical servicing.