Quick summary
GREE GWCD(28)NK6AO carries verified 5-tick NEA registration MELS-SGR-AC220018 until 18 January 2028 at 7.37 kW capacity, 5.63 weighted COP, and 2,803 kWh annual test draw. Its S$873 SP Group Q4 2026 benchmark and S$400 HDB Climate Voucher fit 3-room and 4-room multi-zone homes.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check Gree 7.37 kW Efficiency Ratings and SP Group Cost
Registered under NEA certificate MELS-SGR-AC220018 until 18 January 2028, GREE GWCD(28)NK6AO earns 5 ticks at 7.37 kW total capacity. Lab figures reach 4.98 full-load COP, 6.07 part-load COP, and 5.63 weighted COP. Strong part-load efficiency shines during quiet single-bedroom sleep cycles. Compact HDB families benefit directly from low overnight draw.
NEA records 2,803 kWh/yr annual test usage alongside a S$757 printed label estimate. Multiplying that 2,803 kWh benchmark by late-2026 SP Group billing (31.16 cents/kWh inclusive of GST) produces S$873 yearly. Real household totals move up or down with thermostat set points. Keep indoor vents clear to hold factory efficiency.
Compare Gree 5-Tick Specs and Singapore Flat Fit
Evaluate verified NEA certificate numbers alongside realistic Singapore bedroom and living-room pairing rules:
Scroll to see more columns
| Verified specification | GWCD(28)NK6AO figure | Benchmark comparison | Singapore ownership note |
|---|---|---|---|
| NEA MELS registration | MELS-SGR-AC220018 (5 ticks) | Valid until 18 Jan 2028 | Qualifies for S$400 HDB vouchers |
| Rated cooling output | 7.37 kW Multi Split | 4.98 full / 6.07 part COP | Strong 5.63 weighted efficiency |
| Annual test energy draw | 2,803 kWh yearly | S$757 label vs S$873 SP Q4 | Calculated at 31.16c/kWh tariff |
| Ideal room combination | 3-room / 4-room HDB or compact condo | Two bedrooms + moderate hall | Avoid full simultaneous 4-room sun load |
Match 7.37 kW Multi-Split Output to HDB and Condo Layouts
At 7.37 kW, the outdoor unit outputs roughly 25,150 BTU per hour across connected fan coils. That matches two sleeping bedrooms running nightly at 6.07 part-load COP plus selective living-room sessions. Oversized living areas with west windows still heat rapidly during afternoons.
Avoid running four sunlit rooms together under peak midday heat. Pair quality 22 SWG copper piping and half-inch insulation upfront. Eligible HDB households redeem S$400 Climate Vouchers before December 2027 on verified 5-tick models. Keep condensate slopes steep so wall trunking stays dry.
Plan Your Gree Servicing Cadence and Inspection Checks
Protect that 6.07 part-load efficiency through periodic coil cleaning and careful pre-install ledge checks across every season:
- Verify HDB ledge width and isolators via a S$30 pre-install check (VRV S$80). Checks credit back against installations or fixes with 30-day cover.
- Preserve GREE's 6.07 part-load COP through quarterly general washes: S$50 treats one blower, S$30 each covers two blowers, and S$25 apiece handles three-plus blowers (14-day cover).
- Strip cooking oil or damp biofilm via chemical coil washes. Single rooms bill S$80, paired rooms cost S$70 each, and multi-room jobs of three or more cost S$60 per room carrying 60-day cover.
- Neglected sets clogged with thick mould regain airflow via dismantled overhauls: S$150 solo, S$125/unit for pairs, and S$115/unit across three-plus blowers under 90-day cover.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends

Mitsubishi Electric · Multi-split
Outdoor ledge dripping downstairs: split drain pipe stub
Split outdoor PVC condensate drain stub spilling backed-up water across the ledge
Common Questions
Why does GREE GWCD(28)NK6AO reach 6.07 part-load COP yet 4.98 full-load COP?
Why is the S$873 SP Group figure higher than the S$757 NEA energy label on GWCD(28)NK6AO?
Can HDB owners redeem S$400 Climate Vouchers on GREE GWCD(28)NK6AO?
Is 7.37 kW sufficient to run three sunlit bedrooms and a big living hall together?