GREE GWCD-MS32/O holds NEA 5-tick listing ELS-GAS-AC250040 until 20 March 2028. Tested output reaches 8.51 kW at 5.65 weighted COP and 3,235 kWh yearly. SP Group's 31.16-cent rate puts that benchmark at S$1,008 yearly before S$400 HDB Climate Vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check Gree GWCD-MS32/O Efficiency Metrics and Electricity Cost
Listed on NEA's Energy Labelling register under certificate ELS-GAS-AC250040 through 20 March 2028, GREE GWCD-MS32/O earns 5 ticks at 8.51 kW capacity. Tested performance records 5.06 full-load COP, 6.04 part-load COP, and 5.65 weighted COP.
NEA logs 3,235 kWh yearly test consumption with an S$874 printed label figure. Multiplying 3,235 kWh by the 31.16-cent regulated tariff (GST-inclusive) gives S$1,008 annually, averaging 8.86 kWh daily across test runs.
Strong 6.04 part-load efficiency keeps light overnight bedroom runs frugal compared with running full living-room capacity continuously. Actual monthly SP bills fall well below S$1,008 whenever households cool one or two rooms mostly at night.
Compare Gree GWCD-MS32/O Specs Against Flat Requirements
Review official ELS-GAS-AC250040 performance data alongside Singapore HDB sizing, Climate Voucher terms, and power limits:
Scroll to see more columns
| Model attribute | Verified GREE data | Singapore bill or spec | Flat sizing guidance |
|---|---|---|---|
| NEA registration | ELS-GAS-AC250040 (5 ticks) | Valid until 20 Mar 2028 | Match approved indoor fan coils |
| Cooling & efficiency | 8.51 kW | 5.65 weighted COP | 5.06 full / 6.04 part COP | Fits 4-room or 5-room HDB load |
| Annual energy math | 3,235 kWh test benchmark | S$874 NEA / S$1,008 SP rate | Tariff is 31.16 cents per kWh |
| HDB install checks | 22 SWG copper + Shield CX | S$400 Climate Voucher (to Dec 2027) | Confirm 30A/40A switch headroom |
Size HDB and Condo Rooms and Check Electrical Headroom
At 8.51 kW (about 29,000 BTU), GWCD-MS32/O suits spacious 4-room or 5-room HDB flats and 3-bedroom condos running three bedrooms plus a living hall blower. Compact 3-room flats running mostly two bedrooms overnight gain smoother modulation from smaller outdoor models.
Check main switch amps and HDB Form AC-02 rules early in older 30A resale flats. Qualifying HDB homes claim S$400 Climate Vouchers through late 2027 on verified 5-tick bundles using 22 SWG copper.
Schedule Your Site Check and Quarterly Upkeep Cadence
Keep that 6.04 part-load COP intact from installation day onward with clear survey and cleaning intervals:
- Book a S$30 site survey before purchase to verify ledge clearance and breaker headroom. Survey fees waive on installation or repair (30-day warranty).
- Protect your weighted COP through quarterly general washes. One wall coil bills S$50, paired units cost S$60 total, and four-unit bundles bill S$25 per coil (14-day cover).
- Lift greasy indoor fin lint with chemical washes. Single coils cost S$80, twin setups bill S$70 apiece, and three-plus setups pay S$60 per coil (60-day cover).
- Heavy blower sludge clears through full dismantled cleans. Solo rooms cost S$150, dual rooms bill S$125 each, and three-plus zones run S$115 per zone (90-day cover).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends

Panasonic · Wall-mounted
Warm air after gas top-up: leaking Schrader valve core
Weeping Schrader valve core behind a finger-loose outdoor brass flare cap slowly venting R32 charge over six months while the concealed copper pipe run stays intact