Apply for the 70% EEG Aircon Grant as a Singapore SME

Eligible Singapore SMEs can claim up to 70% of pre-approved aircon hardware costs under the Energy Efficiency Grant, capped at S$30,000 per company per year in the Base Tier. Non-SME firms qualify for up to 30%. File online before signing any purchase order, paying a deposit, or starting site works.

On this page

Quick summary

Singapore SMEs can claim up to 70% of pre-approved aircon hardware costs under the Energy Efficiency Grant Base Tier. Non-SME firms receive up to 30%, capped at S$30,000 per firm each year. The grant pays for hardware only, and you must file before signing a PO or paying a deposit.

Checking SME Eligibility and the S$30,000 Base Tier Cap

The Energy Efficiency Grant Base Tier helps local firms swap old aircons for efficient sets. Singapore SMEs with annual sales up to S$100 million, or up to 200 staff, get up to 70% hardware support.

Larger local firms outside SME limits still receive up to 30% support. Both groups share a Base Tier cap of S$30,000 per firm each year. Your company needs at least 30% local equity and a commercial, retail, or factory site in Singapore.

Every quoted indoor and outdoor model must sit on the live pre-approved list on the day you apply. Single-split sets need an NEA 5-tick badge. Multi-split and VRF sets must also meet listed tick and low-GWP rules.

Separating Grant-Funded Hardware from Excluded Labour Costs

Grant payouts cover qualifying aircon hardware listed on your quote and tax invoice. Labour, copper pipes, removal of old sets, and GST stay outside the grant. Your firm pays those costs on its own.

See how standard project lines split between funded hardware and excluded site work.

Scroll to see more columns

Separating grant-funded hardware from excluded labour costs summary table
Quotation line itemEEG Base Tier treatmentSME funding shareWhat to check on your quote
Pre-approved condenser and fan coilsEligible hardware costUp to 70% (30% non-SME)Exact model codes must match official repository
Standard remote controllers included with setEligible when bundled in model SKUUp to 70% (30% non-SME)Confirm listed under hardware line, not accessory
Installation labour and copper pipingExcluded from grant payout0% (paid by tenant or owner)Must appear as a separate non-hardware line
Dismantling, disposal, and scaffold hireExcluded from grant payout0% (paid by tenant or owner)Itemise clearly so assessors approve hardware fast
9% GST on total project invoiceExcluded from grant payout0% (claim via GST filing if registered)Verify net hardware subtotal before tax

Avoiding the Deposit and Purchase Order Rejection Trap

One rushed step voids your whole claim with no appeal. Never sign a PO, book stock with a deposit, or strip old units before you submit on the Business Grants Portal.

Start with a simple site survey instead. Snowflake Aircon Services charges S$30 for a Singapore survey and waives that fee when you install. We issue a zero-deposit quote that splits eligible hardware from pipes and labour.

Log into the Business Grants Portal with Corppass and upload that clean quote. Wait for the formal Letter of Offer before ordering hardware. Keep delivery orders, bank slips, and model-plate photos ready for your claim.

Checklist Before Submitting on the Business Grants Portal

Missing one file or mixing labour into unit prices slows review by weeks. Run these four checks before clicking submit:

  • Download a fresh ACRA profile showing at least 30% local equity and your business site address.
  • Match each outdoor and indoor model code against the live pre-approved list on filing day.
  • Check that your quote splits hardware prices cleanly from pipes, removal, disposal, and GST.
  • Confirm no PO is signed and no hardware deposit is paid before portal submission.

Common Questions

Can a Singapore SME claim EEG funding for aircon installation labour and copper piping?
Energy Efficiency Grant Base Tier funding reimburses pre-approved aircon hardware only. Labour, copper piping, insulation, old-unit removal, disposal, scaffold hire, and 9% GST fall outside the grant and must sit on separate lines of your quote and final tax invoice.
What happens if my company pays a small deposit before submitting on the Business Grants Portal?
Paying any hardware deposit, signing a PO, or starting site work before you submit on the Business Grants Portal voids the claim at once. Firms should get a zero-deposit quote from a site survey first and wait until filing clears before committing funds.
How much support do non-SME companies receive under the Singapore EEG aircon grant?
Qualifying non-SME firms operating at commercial sites in Singapore receive up to 30% support on pre-approved aircon hardware, compared with up to 70% for local SMEs. Both SME and non-SME applicants share the S$30,000 Base Tier cap per company per year.
Does a S$30 commercial site survey count as starting procurement before grant submission?
Booking a S$30 site survey to inspect old pipes, power points, and room cooling loads does not lock your firm into buying units. As long as no PO is signed and no hardware deposit is paid, your grant claim stays valid.

Sources