Mitsubishi Heavy Industries SRC10YYS-W8 Owner kWh Guide

Tuned for steady overnight bedroom cooling, Mitsubishi Heavy Industries SRC10YYS-W8 pairs 2.53 kW capacity with 4.80 full-load COP and 6.06 part-load COP. Compare August 2027 registration timing, electricity estimates, piping care, and flat servicing options below.

On this page

Quick summary

Certified under NEA listing ELS-WKH-AC240053 until 15 August 2027, Mitsubishi Heavy Industries SRC10YYS-W8 delivers 2.53 kW output at 5.56 weighted COP and 993 kWh yearly benchmark draw. Current Q4 2026 tariffs put annual running cost at S$309 for compact HDB and condo bedrooms.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Examine SRC10YYS-W8 Efficiency and Overnight Draw

Under NEA registration ELS-WKH-AC240053 (valid through 15 August 2027), SRC10YYS-W8 holds 5 ticks at 2.53 kW cooling capacity. Full-load tests log 4.80 COP, stepping up to 6.06 COP under part-load night cruising for a 5.56 weighted figure.

Calculated using Q4 2026 domestic billing of 31.16 cents/kWh plus GST, NEA's 993 kWh annual draw equals S$309 per year, or S$26 monthly. Older stickers print S$268.

HDB buyers redeeming S$400 Climate Vouchers before late 2027 should confirm active listing status around the 15 August 2027 expiry date.

Compare SRC10YYS-W8 Benchmark and Upkeep Fees

Weigh SRC10YYS-W8 registration limits and Snowflake servicing fees side by side before locking in your bedroom setup:

Scroll to see more columns

Compare SRC10YYS-W8 benchmark and upkeep fees summary table
Ownership elementSRC10YYS-W8 recordConfirmed figureBuyer checklist
NEA registrationELS-WKH-AC240053 (5 ticks)2.53 kW | 5.56 weighted COPActive through 15 August 2027
Electricity math993 kWh annual baselineS$309/yr (~S$26 monthly)Label lists older S$268 rate
Light maintenance1 FCU / 2 FCU / 3+ FCUS$50 | S$30 | S$25 per FCU14-day workmanship protection
Chemical treatment1 FCU / 2 FCU / 3+ FCUS$80 | S$70 | S$60 per FCU60-day workmanship protection
Full teardown clean1 FCU / 2 FCU / 3+ FCUS$150 | S$125 | S$115 per FCU90-day workmanship protection

Maintain HDB and Condo Piping on SRC10YYS-W8

At 2.53 kW, SRC10YYS-W8 cools compact bedrooms and home studies up to roughly 15 square metres. Install proper 0.5-inch thermal lagging around 22 SWG copper lines so humid corridors stay drip-free.

Leave clear space above built-in wardrobes so return air enters the top grille smoothly without recirculating cold discharge air. Selecting 25 degrees on quiet auto airflow lets the 6.06 part-load inverter glide smoothly overnight.

Outdoor sun gradually cracks exposed lagging on HDB ledges and condo balconies. Inspect indoor trunking joints during routine cleans for cold sweat spots. Engage an EMA-licensed electrician whenever breaker trips or isolator wear surface. Keeping outdoor condenser fins free from lint prevents warm-weather head pressure trips.

Choose Servicing and Confirm SRC10YYS-W8 Timing

Match maintenance depth to how many hours your bedroom aircon runs weekly. Keeping dust off the blower barrel keeps night decibels low and protects humidity removal across wet monsoon periods:

  • Rinse reusable front screens from floor height fortnightly. Leave exterior ledge tasks and 230V wiring strictly to licensed pros.
  • Step up to chemical treatment if sleep-mode fan airflow drops or damp cardboard odours drift from the louver.
  • Book SRC10YYS-W8 alongside hall or spare-room units so household rates fall into two-unit or three-plus bundles.
  • Troubleshooting callouts cost S$30 per split visit or S$80 for VRV sites, rebated on approved jobs with 30 days of repair coverage.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

How does SRC10YYS-W8 compare with SRC10YVS-W7 for overnight bedroom comfort?
Both are 2.5 kW Mitsubishi Heavy Industries 5-tick single splits. SRC10YYS-W8 delivers higher part-load efficiency at 6.06 COP versus 5.90 COP, suiting steady overnight sleeping runs, while SRC10YVS-W7 carries registration through February 2029.
Does ELS-WKH-AC240053 expire before the S$400 Climate Voucher cutoff?
Certificate ELS-WKH-AC240053 expires on 15 August 2027, whereas HDB Climate Vouchers remain valid through December 2027. Check NEA's Registered Goods portal for renewal status if buying between August and December 2027.
What annual SP Group power bill matches 993 kWh usage on SRC10YYS-W8?
Calculated using Q4 2026 domestic billing of 31.16 cents/kWh plus GST, 993 kWh yearly test draw totals S$309 annually, or about S$26 per month. Older NEA printed stickers display S$268 under prior tariff assumptions.
How much do Snowflake servicing and repair diagnostics cost for SRC10YYS-W8?
Standalone maintenance visits bill S$50 (general), S$80 (chemical), and S$150 (overhaul), dropping to multi-unit rates when paired across two or three-plus blowers. Split callouts run S$30 (S$80 on VRV) and waive on approved work.