Quick summary
Cooking grease and smoke residue cling inside blower wheels and rear drain trays after tenants vacate a Singapore flat. Dismantling indoor fan coils for a chemical overhaul strips stubborn odours before viewings, restoring neutral airflow across HDB and condo bedrooms.
Wall-mounted general servicing $25–$50/unit · chemical wash $60–$80/unit · View servicing rates
Why Wipe-Downs Fail After Heavy Cooking or Smoking
Open-kitchen HDB flats pull wok vapour and cigarette tar past coarse mesh filters. Sticky residue settles across squirrel-cage blower fins, foam backplates, and rear drain gutters.
Quick surface sprays mask sour smells for one afternoon before warm grease odours return. Physical teardown is the only way to clear resin packed behind evaporator coils.
Match Odour Severity to the Right Cleaning Method
Choose the servicing depth matching residue trapped inside your vacated rooms:
Scroll to see more columns
| Tenancy residue sign | Hidden contamination zone | Recommended Snowflake scope | Published flat fee |
|---|---|---|---|
| Light grey dust on filters | Washable mesh and intake grille | General wash (14-day warranty) | 1 unit S$50 | 2 units S$60 total | 3+ units S$25 each |
| Musty sour air at startup | Front coil fins and drain pan | Chemical wash (60-day warranty) | 1 unit S$80 | 2 units S$140 total | 3+ units S$60 each |
| Sticky wok grease or yellow smoke film | Blower barrel, rear pan, backplate | Dismantled overhaul (90-day warranty) | 1 unit S$150 | 2 units S$250 total | 3+ units S$115 each |
| Rattling or weak cooling after clean | Fan bearings, thermistor, coil block | On-site check (30-day repair cover) | S$30 check fee (waived on repair) |
Steps Technicians Take During a Dismantled Coil Overhaul
Technicians isolate the power switch, remove the front shell, and pull the cylindrical fan wheel. They flush front and rear drain channels indoors with non-corrosive cleaner, vacuum pipes, and verify cooling drops.
Residents and cleaning helpers should remain indoors on floor level. MOM and BCA regulations restrict exterior aircon ledge work strictly to trained specialists.
Schedule Post-Tenancy Cleaning Before Agent Viewings Begin
Sequence messy flat works cleanly so fresh coil surfaces stay crisp until handover:
- Complete wall repainting and kitchen degreasing before booking an overhaul. Solvent fumes and sanding dust coat wet aluminium fins if wall trades follow.
- Heavily smoked rooms need a dismantled overhaul. Single units cost S$150, paired rooms run S$125 each, and multi-room flats drop to S$115 per unit with 90-day cover.
- Mild sour odours without tar clear through chemical washing. A solo unit bills S$80, two units total S$140, and three-plus bedrooms pay S$60 apiece with 60-day warranty.
- Keep dated contractor invoices alongside CEA handover photos. Clear baseline proof shields landlords and incoming tenants during future deposit checks.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

EuropAce · Wall-mounted
New wall unit drips in humid weather: bracket out of level
A mounting bracket set slightly out of level, moving the pan's low point off the outlet

Daikin · Wall-mounted
Leaking after servicing: drain insulation left open
Drain insulation left open after a service, letting the cold pipe condense moisture
Common Questions
Can standard general servicing remove cigarette smoke smell from an HDB aircon?
Should landlords book aircon cleaning before or after post-tenancy repainting?
Can landlords deduct chemical overhaul fees from an outgoing tenant's deposit in Singapore?
How long after a chemical overhaul can incoming tenants run the bedroom units?
Sources