On this page
Summary
Likely Causes
- The refrigerant charge was never sized for the actual pipe run.
- Air left in the line at commissioning limits heat transfer.
- A demo or energy-saving mode left on after handover caps the compressor.

Quick Fault Summary
| Likely cause | What to check | Typical next step |
|---|---|---|
| Charge never sized for the pipe run | It has never once cooled properly, from day one. | A technician measures the actual pipe length, compares the charge against what that run needs, and weighs in the correct charge. |
| Air left in the refrigerant line | Cooling is weak evenly, not worse in one room. | A technician recovers the charge, evacuates the line to pull the air out, then weighs in a fresh charge and runs the system to confirm it holds target. |
| A demo or saving mode left on at handover | The unit is unusually quiet for how little it cools. | A technician checks the operating mode and any settings left in place, restores normal operation, then runs the unit to confirm it reaches target. |
- Likely cause
- Charge never sized for the pipe run
- What to check
- It has never once cooled properly, from day one.
- Typical next step
- A technician measures the actual pipe length, compares the charge against what that run needs, and weighs in the correct charge.
- Likely cause
- Air left in the refrigerant line
- What to check
- Cooling is weak evenly, not worse in one room.
- Typical next step
- A technician recovers the charge, evacuates the line to pull the air out, then weighs in a fresh charge and runs the system to confirm it holds target.
- Likely cause
- A demo or saving mode left on at handover
- What to check
- The unit is unusually quiet for how little it cools.
- Typical next step
- A technician checks the operating mode and any settings left in place, restores normal operation, then runs the unit to confirm it reaches target.
1. Charge Never Sized for the Pipe Run
A multi-split cooling weakly from day one ran short on charge. Outdoor units ship for short runs, whereas longer HDB or condo ledge pipe runs need weighed extra gas.
How to Tell
The symptom scales with distance: the rooms furthest along the pipe run suffer most. Air in the line affects every room evenly, and a mode left on responds to a settings change.
- It has never once cooled properly, from day one.
- The rooms furthest from the outdoor unit are the worst.
- It cools a little, so it does not look broken.
- The pipe run to the outdoor unit is long or goes around the flat.
How We Confirm It
A technician measures the actual pipe length, compares the charge against what that run needs, and weighs in the correct charge. Send any handover or commissioning records you have with the WhatsApp message.
The charge is set from the measured pipe run, not topped up by feel. An overcharged system cools worse under load than an undercharged one.
Related Cases
2. Air Left in the Refrigerant Line
Even weakness in every room with near-normal gauge pressure points to air and humid moisture left in the copper line because vacuuming was skipped before release.
How to Tell
Even weakness across the flat, whichever room, points to trapped air. A charge shortfall worsens with distance along the pipe run, and a saving mode clears with a setting change.
- Cooling is weak evenly, not worse in one room.
- It has been like this since handover.
- No setting or fan speed improves it.
How We Confirm It
A technician recovers the charge, evacuates the line to pull the air out, then weighs in a fresh charge and runs the system to confirm it holds target.
Adding more gas on top of trapped air does not fix this. The contamination stays in the circuit, and cooling stays flat.
Related Cases
3. A Demo or Saving Mode Left on at Handover
The unit runs quietly and cools weakly with nothing mechanically wrong. A quiet, eco or demo mode left on after handover keeps the compressor capped, so the room never pulls down.
How to Tell
Here the cause is a setting, not a fault: the unit responds immediately once the mode is cleared, and it runs unusually quiet instead of running hard and failing.
- The unit is unusually quiet for how little it cools.
- An eco, quiet, or saving indicator shows on the remote or app.
- Nothing has ever sounded or looked wrong with it.
- Lowering the setpoint does not make it work harder.
How We Confirm It
A technician checks the operating mode and any settings left in place, restores normal operation, then runs the unit to confirm it reaches target.
A gas top-up does not help here. A capped compressor looks like a weak charge from inside the room, so the mode is ruled out first.