A wall split serving a compact meeting corner in a Kallang SME office runs nonstop all morning at a 20°C setpoint. Staff still feel stuffy air across the conference table, and airflow drops off barely two metres from the louver. The unit never flashes a fault code or shuts down.
- Setup
- Daikin Wall-mounted4-6 yearsOfficeKallang
- Misread as
- Losing an afternoon of meetings to gas top-ups or major commercial repair quotes when a wall split stops keeping up.
- Check first
- Removing the front casing during a lunchtime visit to trace return-air sensor placement and inspect the full evaporator fin face

What Else Produces This
Continuous running with weak discharge usually triggers requests for a quick refrigerant refill. Opening the indoor casing during the quiet lunch hour checks airflow and sensor accuracy first.
Measuring supply air right at the louver reads lukewarm, yet the copper suction pipe feels cold and damp, pointing away from low refrigerant.
Unclipping the outer shell uncovers dense grey mats of office paper lint and sticky grime bridging the lower half of the evaporator fins.
Tracing the thin black return-air thermistor wire shows its sensing bulb popped out of the front coil holder and wedged against the warm rear partition wall.
Checking the blower wheel confirms heavy dust coating along the curved blades, cutting static airflow pressure across the meeting table.
Why It Happens
Small SME offices in Kallang light-industrial blocks run wall units ten hours daily amid printers, cardboard boxes, and humid corridor air. Dust slowly mats the damp evaporator fins, choking heat transfer. Meanwhile, an earlier filter pull nudged the return-air thermistor off its front bracket so it sat against the warm backing wall and kept commanding maximum run time.
What Resolution Involves
Skip unnecessary gas top-ups and protect the meeting desk beneath a clean wash bag. Apply coil-safe chemical cleaner across the matted evaporator fins and flush every passage clear until bright aluminium shows through. Wash the blower blades clean, dry the casing, and snap the return-air thermistor bulb securely back into its front airflow clip.
How to Tell It Worked
Refit the front casing and run the Daikin unit at 23°C before staff return from lunch. Discharge air drops sharply to crisp cooling temperatures, airflow reaches cleanly across the conference table, and the Kallang meeting zone cools down smoothly without straining at 20°C.
Before You Approve a Quote
Check thermistor clip placement and deep fins before blaming gas
- A slipped return-air thermistor touching a warm partition confuses temperature sensing while matted fins throttle airflow.
- Popping off the front casing reveals hidden coil matting that looks clean from the outside mesh filter.
- Re-clipping the sensor and completing a S$80 single-unit chemical servicing restores sharp office cooling without topping up refrigerant.