Midea · Multi-split
A thermometer at a wall unit outlet. A normal outlet reading in a warm room points away from the unit and toward the room, such as furniture blocking the intake.
What Gets Specified
Inside a new Singapore HDB BTO flat, indoor units sit installed while bedroom carpentry is planned around them. One bedroom gets a ceiling-height wardrobe beside the unit because aircon and joinery drawings stayed separate.
Commonly misread as
A newly installed unit that underperforms from the start, with rework needed in a finished room.
What the Drawing Misses
An indoor unit draws air in along its top and front and needs clear space there. The installation manual publishes that space as a minimum clearance for the exact model, and it is almost never carried onto a joinery drawing. The two sheets are compared before anything is built, the only time the fix is simple.
The unit's published minimum clearances define the space its intake needs.
A full-height wardrobe finishing close to the unit cuts that space below the stated figure.
Separate aircon and joinery drawings mean neither trade sees the conflict on its own sheet.
Together they produce a room that runs warm from handover though nothing is faulty.
Services are set out early and interiors designed later, and the two drawings are rarely overlaid. A joiner working to a wall elevation sees a ceiling to build up to, not an intake to keep clear. Each decision is reasonable alone; the clash only shows when the room does not cool.
What Fixes It and How to Verify
Stop the wardrobe short of the required clearance or reposition the unit before the joinery is made, and agree the change with both trades so intake, discharge and service access stay open. After the wardrobe is fitted, every option means rework.
How to tell it worked
The finished gap, measured on site against the manual's figure rather than judged from the floor, and the bedroom cooling like the others. A gap that looks generous from below is often well under what the unit needs.
Before You Sign Off
Lay the joinery drawing over the services drawing
- Indoor units need published clearance at the intake. Joinery drawings do not carry that figure.
- Both decisions are reasonable alone. The failure is that nobody compares the two sheets.
- At drawing stage the fix is a line moved. After the wardrobe is fitted, every option is rework.