How This Presents
A Jurong West HDB bedroom split runs lukewarm through humid nights despite two separate gas refills over recent months. Vent airflow stays brisk yet never turns crisp or cold. The compressor outdoors starts promptly without flashing fault lamps, sparking worries of an expensive hidden indoor coil leak behind the bedroom wall.
- Setup
- Mitsubishi Electric Wall-mounted7-9 yearsHDBJurong West
- Misread as
- Paying S$650 for an indoor coil swap when a Jurong West bedroom unit stays mild after gas refills.
- Check first
- Comparing idle standing pressure against running low-side gauge pull on a Jurong West HDB unit before quoting evaporator coil replacement
- Actual finding
- Overcharged R32 circuit from blind repeat top-ups paired with dusty bedroom fins, raising resting and running head pressure on a healthy coil
- Scope saved
- Servicing or adjustment with no parts replaced

What Else Produces This
Poor cooling right after repeat refills often triggers guesses of a pinholed indoor coil. Reading standing pressure at rest and then running pressure on a low-side dial separates charge loss from overfilling cleanly without guessing.
Connecting a single low-side dial with the Jurong West unit idle records roughly 330 psi, sitting high above normal tropical ambient pressure.
Starting cool mode drops the dial sluggishly while bare suction tubing outside feels warm rather than briskly chilled.
Lifting the front shell uncovers grey lint packed deep between lower evaporator fins behind clean plastic mesh screens.
Checking the condenser outlet temperature confirms elevated head heat caused by too much refrigerant crowding the outdoor coil.
Holding test pressure on the isolated indoor coil later confirms zero pressure drops across twenty quiet minutes.
Why It Happens
Blind gas top-ups dumped extra refrigerant into a closed loop choked by indoor fin dust rather than leaking gas. Excess charge packed the condenser coil and drove resting pressure well above safe tropical limits. High head pressure forced the inverter to throttle down, starving bedroom cooling every night.
What Resolution Involves
Leave sound indoor coils installed and wash matted evaporator fins thoroughly with gentle alkaline coil cleaner. Recover the overcharged refrigerant safely into a clean recovery bottle. Evacuate trapped moisture deeply before charging exact factory R32 weight by digital scale to restore clean cooling balance.
How to Tell It Worked
Watch the low-side gauge dial settle at steady cool mode until running pressure holds cleanly inside factory R32 targets. Supply air inside the Jurong West bedroom turns crisp, dry, and cold within minutes while insulated outdoor tubing sweats lightly with even chill across the suction valve.
Before You Approve a Quote
Compare idle and running pressure before replacing a bedroom coil
- Leaking coils show weak resting pressure even when switched off, whereas overfilled loops sit higher than outdoor ambient heat.
- Dumping blind gas into a dusty Singapore HDB split floods the loop and drives cooling performance down even further.
- Recovering excess refrigerant, clearing trapped air, and weighing exact factory mass restores crisp chill without changing indoor coils.