Refrigerant labels printed inside or beneath indoor fan coils tell homeowners whether their system runs R22, R410A, or R32. Sharing that quick floor-level photo prevents mismatched cylinders and wasted callouts.

On this page

Quick summary

Checking the indoor refrigerant sticker reveals whether an ageing Singapore split runs legacy R22 or modern R32 and R410A gas. Confirming that code from floor level lets technicians bring calibrated cylinders and gauges instead of making wasted trips.

Message us your symptom on WhatsApp

On-site fault check: $30 ($80 VRV), waived if you proceed with repair · See diagnosis & repair

Why R22, R410A, and R32 Gases Never Mix

Older pre-2015 flats still house legacy R22 compressors using mineral oil and lower line pressures. Modern R410A and R32 systems operate near double that pressure with synthetic oils.

Service port threads also differ between 1/4-inch R22 valves and 5/16-inch R410A or R32 fittings. Technicians carrying only R32 cylinders cannot top up R22 loops or blend refrigerants.

Follow EMA, HDB, and MOM Floor-Level Boundaries First

Power off the aircon wall isolator before inspecting any casing edge. HDB, EMA, and MOM rules limit residents strictly to flat indoor flooring.

Never step onto outdoor condenser ledges, balance on chairs, or open 230V junction boxes. Leave brass pipe nuts untouched. Locate the indoor rating plate under the right casing lip or inside the filter lid.

Use This Pass or Fail Self-Check Before Calling

Run these four floor-level checks after switching off the isolator, then compare your result:

Scroll to see more columns

Use this pass or fail self-check before calling summary table
Self-check itemPass signFail warningNext action
Footing and isolatorStanding on floor, switch offOutdoor reach or 230V panelStop; call trained tech
Chassis sticker textClear R22, R410A, or R32 markBlank plate or outdoor-only labelSend model number photo
Filter airflow checkDusty mesh rinses cleanClean mesh still blows warm airSchedule S$30 diagnosis
Copper or coil signsDry fins and steady coolingFrost buildup or hissing soundKeep off; book S$30 test

Verify Leak Causes and Decide on Repair or Replacement

Closed aircon circuits never burn refrigerant like fuel, so low pressure signals either leaks or clogged airflow. Match your issue with published rates:

  • Request a S$30 fault visit first (waived when repair or installation runs; VRV assessments cost S$80), including a 30-day repair guarantee.
  • Dusty meshes often mimic gas shortages; routine maintenance costs S$50 solo, S$30 per FCU in pairs, or S$25 apiece on multi-room flats (14-day workmanship guarantee).
  • Heavier grime calls for chemical washes: single blowers bill S$80, pairs bill S$70 per FCU, while homes with three or more heads run S$60 each carrying a 60-day warranty.
  • Complete dismantled overhauls charge S$150 for one room, S$125 per room in pairs, or S$115 per room across larger flats (90-day warranty); leaking R22 units often warrant 5-tick R32 swaps eligible for S$400 HDB grants until late 2027.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Where is the refrigerant type sticker placed on Singapore indoor wall units?
Manufacturers normally print refrigerant codes on the underside label of the indoor casing or behind the lift-up front filter cover. Always power off the wall isolator first and snap a phone photo from flat floor level.
Can a technician top up R410A or R32 refrigerant into an old R22 aircon?
Mixing R410A or R32 into an R22 chassis damages compressors because working pressures, valve threads, and compressor oils differ sharply. Technicians must recover old gas cleanly, test leaks with dry nitrogen, or recommend replacement.
Should homeowners clean filters before assuming their R22 system needs gas?
Rinsing clogged indoor dust screens from floor level often restores airflow and stops icing that mimics low refrigerant. Whenever washed mesh fails to bring back cool air within twenty minutes, schedule an on-site S$30 check.
When does replacing an old R22 unit beat paying for another refrigerant recharge?
Leaking R22 coils past ten years rarely justify repeated brazing and scarce gas refills. Upgrading to a 5-tick R32 system trims electricity under late-2026 tariffs and unlocks S$400 Climate Vouchers for eligible HDB flats.

Sources

Sources checked 27 Nov 2026

  1. HDB Aircon Home Care GuideHousing & Development Board (HDB) · Checked 27 Nov 2026
  2. EMA Consumer Electrical SafetyEnergy Market Authority (EMA) · Checked 27 Nov 2026
  3. MOM and BCA Ledge Safety CircularMinistry of Manpower (MOM) and BCA · Checked 27 Nov 2026