EIKOU EIK-ACCA65 Multi-Split 5-Tick kWh and Ownership Guide

EIKOU EIK-ACCA65 outputs 6.22 kW cooling at 5.5 weighted COP and 2,517 kWh annually under certificate ELS-EIK-AC260001. Review late-2026 SP Group bill calculations, bedroom capacity limits, and servicing schedules below.

On this page

Quick summary

EIKOU EIK-ACCA65 carries NEA 5-tick registration ELS-EIK-AC260001 at 6.22 kW cooling capacity, 5.5 weighted COP, and 2,517 kWh yearly test use. Valid through 1 January 2029, it qualifies for S$400 HDB Climate Vouchers while keeping night bedroom costs predictable.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Verify EIKOU EIK-ACCA65 Efficiency and SP Group Power Costs

Registered under NEA certificate ELS-EIK-AC260001 until 1 January 2029, EIKOU EIK-ACCA65 holds a 5-tick label. Total rated cooling capacity reaches 6.22 kW across connected rooms. Tested efficiency delivers 4.86 full-load COP, 5.93 part-load COP, and 5.50 weighted COP.

Annual NEA testing logs 2,517 kWh, shown as S$680 on the printed energy label. Under SP Group's 31.16 cents/kWh GST-inclusive tariff, that annual load costs S$784. Actual bills vary with room shading and thermostat habits.

Cooling one bedroom at 25 degrees for eight sleeping hours draws roughly 3.0 kWh nightly. That single-room schedule adds about S$28 monthly. Eligible HDB flats also apply S$400 Climate Vouchers from NEA before year-end 2027.

Compare EIKOU EIK-ACCA65 Specifications and Tariff Benchmarks

Review EIKOU EIK-ACCA65 test metrics alongside practical Singapore running benchmarks below:

Scroll to see more columns

Compare EIKOU EIK-ACCA65 specifications and tariff benchmarks summary table
Specification itemVerified NEA or tariff figurePractical flat contextOwner check note
NEA MELS certificateELS-EIK-AC260001 (5 ticks)Expires 1 January 2029Confirm model code on voucher receipt
Cooling & COP balance6.22 kW | 5.50 weighted COP4.86 full / 5.93 part loadHigh part-load gain suits night sleep
Annual test electricity2,517 kWh/yr (S$680 label)S$784 at 31.16 cents/kWhReflects standard NEA test hours
Voucher eligibilityS$400 Climate VoucherHDB flats until Dec 2027Match NRIC address to NEA list

Match EIKOU EIK-ACCA65 Capacity to HDB and Condo Room Loads

Rated at 6.22 kW (roughly 21,200 BTU/h), EIK-ACCA65 matches two standard bedrooms running together. It also cools three modest rooms gently overnight without straining the compressor.

Avoid pairing this condenser with a hot west-facing living hall plus bedrooms at midday. Daytime multi-room sun load easily pushes demand above 6.22 kW. Check indoor blower sizes carefully before confirming room combinations.

Specify 22 SWG copper tubing, sealed half-inch closed-cell lagging, and dry nitrogen leak checks during installation. Sound piping preserves the 5.93 part-load COP across humid seasons. Up to 50 ft piping per head normally covers standard HDB layouts cleanly.

Plan EIKOU EIK-ACCA65 Servicing Intervals and Pre-Install Checks

Regular coil cleaning maintains steady airflow so the outdoor inverter sustains 5-tick efficiency:

  • Book a S$30 site survey before ordering EIK-ACCA65 to verify ledge brackets and drain slopes. That survey charge is waived when installation proceeds.
  • Single-blower general cleaning bills S$50, and twin blowers drop to S$30 per head. Three or more blowers run S$25 per coil under 14-day warranty.
  • Chemical washes remove sticky bedroom biofilm at S$80 for one head or S$70 each for two. Three-plus setups drop to S$60 per coil with 60-day cover.
  • Dismantled chemical overhauls clear choked drain trays at S$150 for one drum. Twin teardowns cost S$125 each, while three-plus cost S$115 per drum under 90-day warranty.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why does EIKOU EIK-ACCA65 cost S$784 yearly on SP Group instead of S$680?
NEA energy labels estimate annual electricity at an older base rate, putting 2,517 kWh at S$680. Applying SP Group's Q4 2026 GST-inclusive tariff of 31.16 cents/kWh brings the same 2,517 kWh benchmark to S$784.
Can EIKOU EIK-ACCA65 cool a large living room and three bedrooms together?
Rated at 6.22 kW (about 21,200 BTU/h), EIKOU EIK-ACCA65 performs best cooling two to three moderate bedrooms overnight. Running a sunlit living hall plus bedrooms at midday can exceed total condenser capacity.
Does EIKOU EIK-ACCA65 qualify for Singapore HDB Climate Vouchers?
Registered 5-tick multi-split systems like ELS-EIK-AC260001 qualify eligible HDB households for S$400 Climate Vouchers through December 2027. Always confirm exact outdoor and indoor model codes with participating retailers before paying.
How often should Singapore owners service an EIKOU EIK-ACCA65 multi-split?
Nightly bedroom use calls for general servicing every three to four months, costing S$25 per coil across three blowers. Annual chemical washes keep part-load efficiency close to the tested 5.93 COP mark.