On this page
Quick summary
EIKOU EIK-ACCA80 carries active 5-tick listing ELS-EIK-AC250133 until 25 December 2028. Cooling output reaches 7.43 kW with 5.5 weighted COP and 2,984 kWh annual test consumption. Current electricity rates price that benchmark at S$930 yearly before S$400 HDB vouchers.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Review EIKOU EIK-ACCA80 Ratings and SP Group Electricity Cost
Certificate ELS-EIK-AC250133 registers EIKOU EIK-ACCA80 with five green ticks until 25 December 2028. Total cooling output reaches 7.43 kW (around 25,350 BTU/h). Official laboratory figures stand at 4.86 full-load COP, 5.92 part-load COP, and 5.5 weighted COP.
Published test draw equals 2,984 kWh yearly, shown as S$806 on printed energy stickers. Applying 31.16 cents/kWh (late-2026 GST-inclusive tariff) lifts annual benchmark cost to S$930. Eligible HDB flats can offset purchase cost with S$400 in NEA vouchers active until December 2027.
Compare EIKOU EIK-ACCA80 Specs and Annual Bill Scenarios
Inspect verified EIKOU EIK-ACCA80 register metrics alongside current utility figures and room usage patterns:
Scroll to see more columns
| Verified rating line | EIKOU EIK-ACCA80 spec | Late 2026 cost math | Flat ownership note |
|---|---|---|---|
| NEA MELS certificate | ELS-EIK-AC250133 (5 ticks) | Valid until 25 Dec 2028 | S$400 HDB voucher eligible |
| Cooling and COP profile | 7.43 kW | 5.5 weighted COP | 4.86 full / 5.92 part | Strong light-load efficiency |
| Annual test energy | 2,984 kWh/yr NEA log | S$930/yr vs S$806 label | Priced at 31.16 cents/kWh |
| Single sleep cycle | 8h bedroom at 25 degrees | ~2.5 to 3.2 kWh nightly | ~S$23 to S$30 monthly/room |
Match 7.43 kW Multi-Split Capacity to HDB and Condo Flats
At 7.43 kW combined output, EIK-ACCA80 fits three-bedroom HDB or compact condo layouts cooling three bedrooms together, or two sleep zones plus occasional living use. Pushing heavy daytime hall loads forces operation closer to its 4.86 full-load efficiency.
Running one or two bedrooms overnight keeps inverter demand near its 5.92 part-load rating. Pair new installations with 22 SWG copper piping and half-inch closed-cell insulation so refrigerant lines stay dry and leak-free over ten-year lifespans.
Schedule EIKOU EIK-ACCA80 Servicing and Inspection Intervals
Keep part-load efficiency high and drain trays clear with regular multi-split servicing:
- Arrange a S$30 pre-purchase layout survey, waived when installation proceeds, to inspect HDB ledge spacing before ordering EIK-ACCA80.
- Preserve rated efficiency with routine servicing: S$50 when servicing one blower, S$30 each when servicing two, and S$25 per blower across three or more (14-day warranty).
- Flush damp aluminum fins using chemical servicing when airflow drops. Rates sit at S$80 for one head, S$70 per head for a pair, or S$60 each on three-plus setups (60-day assurance).
- Strip heavy drum slime via dismantled overhauls (S$150 single coil, S$125 each for two coils, S$115 per coil across three-plus homes; 90-day assurance), or book S$30 fault testing if cooling dips.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Heavy Industries · Wall-mounted
One room warm on a multi-split: coil buildup, not low gas
Coil and airflow restriction confined to the single affected indoor unit

Mitsubishi Electric · Wall-mounted
Warm air with normal gas pressure: fouled coil, not low gas
Grease-choked indoor evaporator coil and dust-packed blower wheel causing poor temperature drop while refrigerant pressure stayed full
Common Questions
Why does EIKOU EIK-ACCA80 list S$806 on the NEA label versus S$930 at SP Group tariffs?
Does EIKOU EIK-ACCA80 qualify for Singapore's S$400 NEA Climate Vouchers?
Why is EIK-ACCA80 part-load COP (5.92) higher than its full-load COP (4.86)?
How often should owners service a 5-tick EIKOU multi-split to preserve kWh savings?