Enovatek Energy EES-ADC12GW-XA-32R+5 kWh Guide

Enovatek Energy EES-ADC12GW-XA-32R+5 pairs 3.52 kW cooling with 5.53 weighted COP and 1,384 kWh yearly test use under MELS-ENE-AC210036. Compare SP Group bill numbers and upkeep schedules below.

On this page

Quick summary

Enovatek Energy EES-ADC12GW-XA-32R+5 holds NEA 5-tick certificate MELS-ENE-AC210036 valid until 10 May 2027 at 3.52 kW cooling capacity, 5.53 weighted COP, and 1,384 kWh yearly consumption. Using SP Group's 31.16-cent GST-inclusive tariff, that annual benchmark runs S$431.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Verify Enovatek Energy NEA Data and SP Group Yearly Cost

Holding NEA certificate MELS-ENE-AC210036 through 10 May 2027, Enovatek Energy EES-ADC12GW-XA-32R+5 earns 5 green ticks at 3.52 kW cooling output. Efficiency reaches 4.89 full-load COP, 5.95 part-load COP, and 5.53 weighted COP. Confirm active portal validity before paying any deposit since registration ends in May 2027.

Annual label usage totals 1,384 kWh, printed at S$374 on the green sticker under NEA's 27-cent reference calculation. Using SP Group's 31.16-cent GST-inclusive domestic tariff, 1,384 kWh costs S$431 per year—around S$35.90 each month. Eligible public-housing households receive S$400 in Climate Friendly Households support for 5-tick aircon purchases redeemed before end-2027.

Compare EES-ADC12GW-XA-32R+5 Specs and Room Fit

Review verified MELS-ENE-AC210036 parameters alongside practical Singapore bedroom sizing and registration expiry checks. Matching 3.52 kW to mid-sized rooms avoids constant on-off cycling. West-facing bedrooms with wide glass windows also benefit from this reserve cooling capacity.

Scroll to see more columns

Compare EES-ADC12GW-XA-32R+5 specs and room fit summary table
Ownership parameterEnovatek EES-ADC12GW-XA-32R+5NEA verified figureLocal selection guidance
Certificate expiryMELS-ENE-AC210036 (5 ticks)Expires 10 May 2027Check active listing before order
Output & COP balance3.52 kW single split4.89 full; 5.95 part COPSuits master bedroom or study
Yearly test cost1,384 kWh annual draw5.53 weighted COPS$374 label vs S$431 SP bill
HDB voucher & tariffS$400 voucher eligible31.16c/kWh current tierRoughly S$35.90 monthly test draw

Keep Single-Split Master Bedrooms Cool Without Extra Draw

Cooling 3.52 kW matches larger HDB master bedrooms, partitioned studies, or enclosed dining corners well. Part-load efficiency hits 5.95 COP once room temperatures settle near 25 degrees overnight without harsh fan noise. Setting sleep timers prevents excess dawn runtime during cool mornings.

Rinse washable indoor mesh filters every two to four weeks from floor level to prevent airflow drop and frost. Flush condensate pans periodically so humid drainage flows cleanly into floor traps. Keep 230V switches and outdoor condenser ledge maintenance strictly for trained technicians or certified electrical workers.

Plan EES-ADC12GW-XA-32R+5 Servicing and Inspection Intervals

Consistent cleaning protects compressor bearings and keeps monthly electricity totals predictable:

  • On-site fault inspections start at S$30 and become complimentary once repairs or fresh unit installations proceed, protected for 30 days.
  • Quarterly general washes cost S$50 (lone indoor head), S$30 apiece (pair of heads), or S$25 apiece (three-plus heads) backed by 14-day assurance.
  • Odour-removing chemical cleans price out at S$80 for one indoor coil, S$70 per coil on pairs, or S$60 per coil across three-plus coils (60-day cover).
  • Deep dismantled overhauls clear choked drains at S$150 for one coil, S$125 per coil on two, and S$115 per coil when servicing three or more units under 90-day coverage.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why does the Enovatek EES-ADC12GW-XA-32R+5 certificate expire on 10 May 2027?
NEA registration certificates carry fixed validity periods and must be renewed or updated by the importer before expiry. Verify MELS-ENE-AC210036 stays active on the NEA portal on your purchase date.
What room sizes work best for the 3.52 kW Enovatek EES-ADC12GW-XA-32R+5?
Outputting 3.52 kW suits a warm master bedroom, enclosed home office, or small studio around 15 to 22 sqm. Compact common bedrooms often run more comfortably on smaller 2.5 to 2.9 kW units.
How is the S$431 SP Group annual estimate calculated for Enovatek EES-ADC12GW-XA-32R+5?
Multiplying 1,384 kWh against Singapore's regulated 31.16-cent rate (inclusive of GST) equals S$431 across twelve months. Actual household bills shift with nightly sleep hours, setpoints, and afternoon sun exposure.
Can homeowners claim S$400 Climate Vouchers on Enovatek EES-ADC12GW-XA-32R+5?
Eligible HDB flats may apply S$400 Climate Friendly Households vouchers toward listed 5-tick residential single splits before end-2027. Check retailer participation and live NEA status prior to ordering.