On this page
Quick summary
A Hitachi indoor unit that drips while still cooling has a drain problem. Drips only on humid days point to a scale-narrowed bore. Drips within days of a service point to something left in the drain path. A drip after a power cut on a ceiling unit points to a stuck condensate pump.
Start with When It Started, Not Where It Drips
Start with timing, not puddle location. The first drip date and recent changes usually identify the fault.
Leaks happen when condensate stalls between the coil tray and outdoor outlet. A room that still cools normally points to a drain issue, not a refrigerant fault.
Drain faults follow triggers: humid spells, recent servicing, power cuts or years of gradual buildup.
What the Pattern in the Dates Points To
Intermittent drips point to capacity limits; sudden leaks after an event belong to that event. A quick log of wet and dry days beats a stain photo.
| When the water appears | What that pattern points to | What it is usually not |
|---|---|---|
| Only on humid days, dry otherwise | A drain narrowed by years of mineral scale | A cracked pipe inside the wall |
| Within days of a service visit | Something left in place during that visit | A blockage that formed on its own |
| Within a day of a building power cut | A condensate pump stuck in its safety state | A burnt out pump motor |
| Same rate every day, wet or dry | A split pipe or a fully closed line | A volume problem |
| From the first weeks after installation | Fall or routing set wrong at the start | Wear or age |
Two Dates Worth Writing Down
Note the day water first showed and the last date anyone worked near the unit, such as servicing, a repair or shelf work near trunking. Also note if the drip stops and restarts.
Intermittent Dripping Is a Bore Problem, Not a Break
Humid-day-only leaks rarely mean cracked pipes, because cracks leak steadily in any weather. Humidity boosts condensate volume.
Minerals settle at pipe joints over ten or more years, narrowing the bore without sealing it shut.
Normal output clears the pinch, but heavy humid afternoons overwhelm it and back water over the tray lip.
Technicians trace the line to the outlet, inspect joints and clear the narrowed section directly. Tray-end flushing alone misses downstream scale, and scale does not require hacking walls to replace buried pipes.
A Pump Can Be Stuck Rather Than Broken After a Power Cut
Cassette and concealed ceiling units rely on condensate pumps, whereas wall units drain by gravity alone.
Power cuts often flicker as supply returns, locking a pump in safety stop. The aircon cools normally, yet water fills the tray and drips within a day.
A silting pump degrades gradually; a stuck pump runs fine for weeks between outages, then stops completely.
Clearing that lockout follows the pump maker's procedure inside the ceiling void and needs a technician.
Before Agreeing to a New Pump
Replace a pump only after cleaning the chamber, float, hose and inlet and testing post-reset. A running pump that still backs up indicates a blocked hose or control fault.
The Cheap Checks That Come First
Run three quick checks before approving major quotes.
First, check the drain outlet cap, which servicing can leave sealed behind closed panels if leaking began within a week of a visit.
Second, on ceiling units dripping after a power cut, keep the unit off and check the pump reset.
Third, trace the drain run and joints; it costs far less than wall hacking and resolves most intermittent leaks.
Switch off immediately if water hits wiring, sockets or ceiling structures. Otherwise keep it off so the coil stops feeding water.
Drain faults leave physical proof: tray sludge, joint scale, a capped outlet or a dead pump. Quotes proposing hacking, pump swaps or chemical overhaul without that evidence are guesswork.