Is Mitsubishi Heavy Industries aircon good?
Yes, as equipment: MHI household splits are registered with NEA at 4 and 5 ticks. The weak points are in ownership, mainly a 14-day registration window and a warranty that never pays labour.
The strengths and watch points below come from the NEA register and MHI's own Singapore terms.
| Aspect | What works | What to watch |
|---|---|---|
| Efficiency | SRC single splits at 4 or 5 ticks; SCM multi-splits all at 5 | Compare weighted COP within the same capacity band |
| Range | Single splits from 2.5 to 7.1 kW; multi-splits from 4.3 to 8.0 kW | Indoor and outdoor units pair only within MHI's own combinations |
| Compressor cover | 5 years on the compressor | Labour, transport and refrigerant charging excluded, even in year one |
| Registration | One rule: register with KM Marketing | Miss the 14 days from purchase and the warranty is not effective |
| Warranty repairs | One route: KM Marketing or its appointed agents | A repair by anyone else puts the claim at risk |
| Second-hand units | The unit itself can still be serviced and repaired | Change of ownership is outside MHI's warranty |
Who an MHI system suits
An MHI system suits a buyer who registers it on installation day and keeps to a servicing schedule. MHI's terms do not cover damage caused by poor maintenance.
Its Singapore FAQ asks owners to have units inspected and maintained regularly by a certified service company.
- Good fit: a new system installed and registered by an MHI dealer.
- Good fit: replacing an MHI indoor unit on a working MHI outdoor unit.
- Weaker fit: a second-hand MHI unit, since change of ownership is outside the warranty.
What the common MHI codes point to
MHI's indoor display shows faults as E-codes. Each code names a circuit, so the check starts there before any part is quoted.
An E35 and an E36 both stop the outdoor unit, but for different reasons. The registry lists low gas as a cause of E36, not of E35.
| MHI code | What it means | Causes the registry lists |
|---|---|---|
| E7 | Room temperature sensor | The sensor or its connection |
| E9 | Drain fault | The drain pan, pipe or float |
| E16 | Indoor fan motor error | The fan motor or its wiring |
| E35 | Cooling high pressure protection | Overload, overcharged refrigerant, a broken outdoor coil sensor wire, or a closed service valve |
| E36 | Compressor overheat | Low gas, a faulty discharge pipe sensor, or a closed service valve |
Before you buy or keep one
Register the unit within 14 days and keep the confirmation. Ask the installer who holds parts for the model, and file each servicing invoice alongside the purchase receipt.
The Mitsubishi Electric or Heavy Industries comparison sets the two Mitsubishi warranties side by side. For MHI against Panasonic, see the Mitsubishi Heavy vs Panasonic guide.