Midea MAS-1S12D holds NEA 5-tick certificate ELS-MDS-AC240060 with 3.59 kW cooling, 5.5 weighted COP, and 1,466 kWh annual test consumption until 21 November 2027. SP Group's 31.16-cent tariff puts annual benchmark bills at S$457, suiting larger bedrooms and enclosed living-study rooms.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Review MAS-1S12D NEA Efficiency and SP Group Power Bills
Certified under ELS-MDS-AC240060 until 21 November 2027, Midea MAS-1S12D delivers 3.59 kW cooling (12,250 BTU/h) using R32 refrigerant. Laboratory testing records 4.47 full-load COP, 6.18 part-load efficiency, and 5.5 weighted COP.
Official NEA testing measures 1,466 kWh annually, showing S$396 on the green label. Using SP Group's 31.16-cent Q4 2026 GST-inclusive charge puts annual label power at S$457, or S$38.08 monthly.
Overnight eight-hour duty at 25 degrees typically consumes 3.4 to 4.1 kWh, costing S$32 to S$38 monthly. Qualifying HDB homeowners deduct S$400 using Climate Vouchers before 2028 begins.
Compare MAS-1S12D Rated Specs and Annual Running Figures
Benchmark MAS-1S12D metrics against Singapore utility tariffs and voucher offsets before buying:
Scroll to see more columns
| Performance metric | MAS-1S12D published figure | Local utility impact | Buyer context |
|---|---|---|---|
| NEA certificate & ticks | ELS-MDS-AC240060 (5 ticks) | Expires 21 November 2027 | S$400 Climate Voucher eligible |
| Capacity & COP spread | 3.59 kW | 5.5 weighted COP | 4.47 full / 6.18 part load | Strong part-load sleep savings |
| Standard annual usage | 1,466 kWh test benchmark | S$396 NEA vs S$457 SP bill | Uses 31.16c GST-in Q4 tariff |
| Overnight room budget | 3.4 to 4.1 kWh per 8h run | About S$32 to S$38 monthly | Fits 16 to 22 sqm spaces |
Match MAS-1S12D 3.59 kW Capacity to HDB and Condo Spaces
With 3.59 kW output, MAS-1S12D suits 16 to 22 sqm master rooms, sunny study zones, or afternoon-heat lounges. Putting 12,000 BTU capacity inside tiny 9 sqm rooms triggers short cycles and clammy air.
Independent 1-to-1 piping isolates one room from ageing multi-split condensers. Specify heavy-wall 22-gauge copper piping, Armaflex half-inch insulation, and a 20A double-pole power switch.
Plan MAS-1S12D Upkeep Cadence and Pre-Install Surveys
Keep 6.18 part-load efficiency sharp and drain trays dry through predictable maintenance:
- Pre-install assessments checking wall brackets, drains, and power cost S$30 (S$80 VRV), credited toward mounting or 30-day warranted repairs.
- Routine quarterly servicing runs S$50 for one solitary unit, dropping to S$30 for pairs or S$25 across larger multi-unit bookings (two-week guarantee).
- Annual chemical flushes remove grease buildup at S$80 standalone, S$70 paired, or S$60 across three-plus heads, backed by two-month cover.
- Full dismantled chemical overhauls clear blocked pans for S$150 on one indoor head, S$125 per head on pairs, or S$115 each when servicing three or more units (three-month guarantee).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Wall-mounted
Warm air with normal gas pressure: fouled coil, not low gas
Grease-choked indoor evaporator coil and dust-packed blower wheel causing poor temperature drop while refrigerant pressure stayed full

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends
Common Questions
Can HDB homeowners claim S$400 Climate Vouchers on Midea MAS-1S12D?
Why is MAS-1S12D oversized for a small 9 sqm HDB common room?
How does MAS-1S12D handle Singapore's late-2026 electricity rate?
Which installation piping spec prevents sweating on MAS-1S12D lines?