On this page
Quick summary
Midea MEZ-1S09E holds NEA certificate ELS-MSP-AC260033 with 5 energy ticks, 2.74 kW output, 5.53 weighted COP, and 1,121 kWh yearly test use until 24 March 2029. Priced using late-2026 utility tariffs (31.16 cents per kWh), standard benchmark power totals S$349 annually across compact HDB bedrooms.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check MEZ-1S09E NEA Registration and Late-2026 Tariff Math
Listed under ELS-MSP-AC260033 until 24 March 2029, Midea MEZ-1S09E outputs 2.74 kW cooling (9,350 BTU/h) on R32 gas. Verified lab results show 4.41 full-load COP, 6.27 part-load rating, and 5.53 weighted COP.
Standardized yearly energy stands at 1,121 kWh, displaying S$303 on the NEA tick badge. Under SP Group's prevailing GST-included rate of 31.16 cents per kWh, 1,121 kWh works out to S$349 yearly (S$29.08 monthly).
Sleeping eight hours at 25 degrees typically pulls 2.4 to 2.9 kWh nightly, costing S$22 to S$27 monthly. Public-housing buyers deduct S$400 Climate Vouchers until 31 December 2027.
Compare MEZ-1S09E Test Numbers and Bedroom Suitability
Review MEZ-1S09E lab metrics alongside local tariff bills and common-room fit:
Scroll to see more columns
| MEZ-1S09E parameter | Certified value | Tariff / field outcome | Sizing note |
|---|---|---|---|
| Listing & validity | ELS-MSP-AC260033 (5 ticks) | Expires 24 March 2029 | Clears S$400 HDB voucher rules |
| Capacity & COP range | 2.74 kW | 5.53 weighted COP | 4.41 full / 6.27 part load | Balanced 9k output for night use |
| Test annual energy | 1,121 kWh yearly draw | NEA tick S$303 vs S$349 SP | Priced on 31.16c GST-in rate |
| Sleep cycle draw | 2.4 to 2.9 kWh over 8h | Roughly S$22 to S$27 monthly | Ideal for 9 to 14 sqm rooms |
Evaluate MEZ-1S09E Sizing Limits in HDB and Condo Rooms
At 2.74 kW, MEZ-1S09E matches 9 to 14 sqm common HDB bedrooms, study corners, and helper quarters smoothly. Installing 9,000 BTU capacity inside hot 18 sqm halls forces constant full-load runs.
Standalone 1-to-1 piping keeps spare rooms independent from older multi-split outdoor units. Specify thick-gauge 22 SWG copper lines, 12.7 mm elastomeric lagging, and a 20-ampere isolator wired by a licensed electrical worker.
Schedule MEZ-1S09E Commissioning and Recurring Servicing
Clean evaporator coils preserve MEZ-1S09E modulation savings and keep indoor pans bone-dry:
- Site surveys inspecting drain fall and bracket clearance charge S$30 upfront, waived completely when mounting proceeds (VRV surveys S$80, 30-day warranty).
- Quarterly general cleaning stays affordable: pay S$25 apiece for three-plus splits, S$30 apiece for two, or S$50 solo with 14-day warranty.
- Damp coil scale clears through chemical servicing: three-plus units charge S$60 each, pairs cost S$70 each, and solo units cost S$80 (60-day warranty).
- Mouldy blower wheels require full teardown chemical overhauls at S$115 each (three-plus), S$125 each (two), or S$150 (one), guaranteed 90 days.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Cassette
Cassette not cooling: stuck gas-flow valve, not compressor
A flow-control valve stuck part-closed, restricting refrigerant to the indoor coil

LG · Wall-mounted
LG CH35 error: gas leak at the outdoor connections
Refrigerant leak at corroded outdoor unit pipe connections
Common Questions
What separates MEZ-1S09E from a 3.59 kW single split in Singapore bedrooms?
How much does Midea MEZ-1S09E add to monthly SP Group bills?
Does Midea MEZ-1S09E qualify for HDB Climate Vouchers?
Which electrical isolator does a single-split MEZ-1S09E installation require?
Sources
Sources checked 27 Nov 2026