Mitsubishi Heavy Industries SRC13YYS3-W8 earns 5 NEA ticks under ELS-WKH-AC260035 through 18 May 2029, delivering 3.49 kW cooling at 5.53 weighted COP and 1,384 kWh yearly use. Calculated at 31.16 cents on late-2026 SP Group meters, annual test power totals S$431 for warm master bedrooms.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Compare SRC13YYS3-W8 Energy Ratings and SP Group Electricity Math
Holding NEA certificate ELS-WKH-AC260035 until 18 May 2029, Mitsubishi Heavy Industries SRC13YYS3-W8 (paired alongside SRC13YYS2-W8A) posts 5 ticks at 3.49 kW capacity. Rated efficiency hits 4.65 full-load COP, 6.11 part-load COP, and 5.53 weighted COP. Checking the YYS3 suffix avoids receiving the older 4-tick SRC13YYS-W8 model rated at 1,413 kWh.
Annual benchmark testing measures 1,384 kWh, marked S$374 on the energy tag. SP Group bills 31.16 cents per unit in late 2026 (GST paid), bringing yearly benchmark power to S$431, or nearly S$36 monthly. Eligible HDB buyers retain S$400 Climate Vouchers until late 2027 on verified 5-tick sets.
Evaluate SRC13YYS3-W8 Specs for HDB and Condo Rooms
Review certified NEA parameters alongside Singapore room sizing and HDB installation conditions:
Scroll to see more columns
| Evaluation factor | SRC13YYS3-W8 figure | Official benchmark | Practical flat note |
|---|---|---|---|
| NEA COR registration | ELS-WKH-AC260035 (5 ticks) | Valid to 18 May 2029 | Outscores 4-tick SRC13YYS-W8 sibling |
| Output & efficiency | 3.49 kW (~11,910 BTU/h) | 4.65 full / 6.11 part COP | 5.53 weighted COP handles afternoon heat |
| Yearly test consumption | 1,384 kWh benchmark draw | S$374 NEA; S$431 SP bill | Near S$36 monthly at 31.16c/kWh |
| Room & install standard | Master room or study | BCA-trained installer required | Fits 140 to 210 sq ft sunlit rooms |
Check HDB Installation Limits and Mitsubishi Heavy Fault Care
At 3.49 kW (~11,910 BTU/h), SRC13YYS3-W8 fits sun-exposed HDB master rooms, condo suites, or busy home offices spanning 140 to 210 square feet. HDB rules require BCA-trained installers, sound brackets, and power-point checks before mounting another condenser outside.
Specify 22 SWG copper piping wrapped in half-inch closed-cell lagging to stop trunking drips along damp corridors. Because local MHI parts stockists are fewer than Starmex networks, keep servicing records tidy and confirm stock before fixing E5 signal or E35 high-pressure alerts.
Schedule SRC13YYS3-W8 Installation Surveys and Routine Servicing
Keep evaporator fins clean and drainage flowing smoothly using transparent Snowflake maintenance tiers:
- Site surveys and fault checks bill S$30 (split units) and S$80 (VRV equipment). Approved installation or repair deducts the charge with 30-day cover.
- Dry brush servicing and drain vacuuming cost S$50 for one split. Two splits run S$30 each, while three or more pay S$25 apiece under 14-day cover.
- Chemical coil flushing removes sticky buildup, costing S$80 for one wall coil. Pairs bill S$70 per coil, and three-plus units run S$60 per coil (60-day cover).
- Full blower teardowns clear recurring pan algae at S$150 for one unit. Twin units cost S$125 apiece, and three-plus sets cost S$115 apiece (90-day cover).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Multi-split
Outdoor ledge dripping downstairs: split drain pipe stub
Split outdoor PVC condensate drain stub spilling backed-up water across the ledge

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends