On this page
Quick summary
Bearing NEA approval MELS-WIN-AC220028 through 25 April 2028, Fujitsu AOAH36CBTA delivers 10.21 kW across 5 green ticks with 6 weighted COP and 3,720 kWh test draw. Under Singapore's 31.16-cent Q4 tariff, annual benchmark power totals S$1,159, matching shops, offices, and large halls.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Verify AOAH36CBTA NEA Ratings and Annual Electricity Cost
Active under registration MELS-WIN-AC220028 until 25 April 2028, Fujitsu AOAH36CBTA outputs 10.21 kW with 5 green ticks. Efficiency hits 5 full-load COP, 6.67 part-load COP, and 6 weighted COP.
Energy labels print 3,720 kWh annual consumption and a S$1,004 base figure. Applying Singapore's 31.16-cent GST-inclusive Q4 2026 rate puts 3,720 kWh at S$1,159 annually, or S$96.60 monthly. Business premises on commercial retail tariffs pay different daytime rates than domestic flats.
Compare AOAH36CBTA Capacity and Singapore Premises Fit
Inspect official NEA test numbers beside electrical load and space clearances. Reviewing these specs early prevents costly wiring surprises on installation day:
Scroll to see more columns
| Audit metric | Fujitsu AOAH36CBTA spec | Published reference | Deployment consideration |
|---|---|---|---|
| NEA registration | MELS-WIN-AC220028 (5 ticks) | Valid to 25 Apr 2028 | Eligible SMEs can check EEG |
| Cooling and efficiency | 10.21 kW (~34,800 BTU) | 5 full / 6.67 part COP | 6 weighted COP modulation |
| Annual test energy | 3,720 kWh/yr NEA label | S$1,004 label figure | S$1,159 yearly at 31.16c rate |
| Suitable premises | 55 to 85 sqm open bays | High-amp dedicated isolator | Too large for HDB bedrooms |
Match 10.21 kW Cooling Cleanly to Large Open Zones
Pushing roughly 34,800 BTU through one indoor coil makes Fujitsu AOAH36CBTA right for retail shops, classrooms, offices, and large landed halls. Small bedrooms would face fierce drafts and rapid cycling.
Ask an EMA Licensed Electrical Worker to check circuit ampacity and isolator sizing before delivery. Place outdoor condensers clear of kitchen exhaust hoods or tight alley walls so heat escapes freely. SMEs replacing older splits can also verify GoBusiness Energy Efficiency Grant rules first.
Choose the Right AOAH36CBTA Survey and Servicing Plan
Heavy commercial airflow draws lint and soot rapidly, so regular washes preserve that 6.67 part-load efficiency:
- Pre-install surveys cost S$30 on splits (S$80 for VRV buildings) and waive on approved work. Repair parts hold 30-day warranty.
- Standard servicing covers dust and drain checks. One FCU costs S$50, two cost S$30 per FCU, and three-plus cost S$25 each (14-day warranty).
- Shopfront grease needs chemical coil flushing. One unit costs S$80, two units bill S$70 apiece, and three-plus units bill S$60 apiece with 60-day warranty.
- Blocked condensate pans need full overhauls. One FCU costs S$150, two cost S$125 per coil, and three-plus cost S$115 per coil with 90-day warranty.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Fujitsu · Cassette
Office cassette dripping at louver: sweating from fouled coil
Surface condensation on the supply louver driven by restricted airflow across one fouled coil face

Mitsubishi Electric · Multi-split
Outdoor ledge dripping downstairs: split drain pipe stub
Split outdoor PVC condensate drain stub spilling backed-up water across the ledge
Common Questions
Can a standard HDB flat install the 10.21 kW Fujitsu AOAH36CBTA single split?
What does 3,720 kWh annual energy cost for Fujitsu AOAH36CBTA in Singapore?
Does Fujitsu AOAH36CBTA qualify for the Singapore Energy Efficiency Grant?
How often should shops service a 10.21 kW Fujitsu single split?
Sources
Sources checked 27 Nov 2026