Mitsubishi Heavy Industries SCM25YS-W kWh Guide

Mitsubishi Heavy Industries SCM25YS-W pairs 4.32 kW output with a 6.24 part-load COP across 1,805 kWh annual test consumption under ELS-WKH-AC250132. Review SP Group costs, twin-room sizing, and servicing schedules below.

On this page

Quick summary

Mitsubishi Heavy Industries SCM25YS-W carries NEA 5-tick registration ELS-WKH-AC250132 at 4.32 kW cooling capacity, 5.52 weighted COP, and 1,805 kWh yearly test use. Compact twin-room sizing, S$400 HDB Climate Vouchers, and high 6.24 part-load efficiency suit two-bedroom flats and studies.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Review SCM25YS-W Efficiency Ratings and SP Group Electricity Cost

Registered under NEA certificate ELS-WKH-AC250132 through 25 December 2028, Mitsubishi Heavy Industries SCM25YS-W earns 5 green ticks at 4.32 kW rated cooling output. Tested efficiency stands at 4.43 full-load COP, 6.24 part-load COP, and 5.52 weighted COP.

Annual test energy totals 1,805 kWh, listed as S$487 on the NEA label. At the 31.16 cents/kWh Q4 2026 SP Group rate (including GST), that benchmark equals S$562 yearly or roughly S$47 monthly.

Compare SCM25YS-W Certified Specs and Household Fit

Check certified NEA efficiency figures alongside SP Group bill impacts and Singapore flat sizing notes:

Scroll to see more columns

Compare SCM25YS-W certified specs and household fit summary table
Ownership factorVerified SCM25YS-W dataBill or rebate figureSingapore flat takeaway
NEA MELS registrationELS-WKH-AC250132 (5 ticks)Valid until 25 Dec 20284.32 kW total multi-split capacity
COP performance profile5.52 weighted COP4.43 full; 6.24 part loadExcels running one room overnight
Annual test energy draw1,805 kWh/yr NEA benchmarkS$487 NEA; S$562 SP Q4 rateAbout S$47 monthly at 31.16c/kWh
HDB voucher eligibilityQualifying 5-tick multi-splitUp to S$400 HDB offsetRedeemable until 31 Dec 2027
Site survey before installPipe, ledge, and isolator checkS$30 survey (waived on work)Verifies twin-room routing cleanly

Match 4.32 kW Capacity to Two-Room HDB and Condo Layouts

Total cooling output of 4.32 kW translates to roughly 14,740 BTU/hr across connected fan coils. That envelope suits a compact System 2 pairing—typically a 9,000 BTU master bedroom plus a 9,000 BTU common room or study—in 3-room HDB flats and 2-bedroom condos.

Avoid stretching a 4.32 kW condenser across three busy rooms or a sunlit living hall simultaneously. Eligible HDB households can still apply S$400 Climate Vouchers until 31 December 2027 on qualifying 5-tick sets.

Plan SCM25YS-W Installation Surveys and Routine Servicing

Lock in tidy pipe lagging and steady quarterly upkeep so part-load COP stays close to 6.24 over time:

  • Book an initial installation survey for S$30 to inspect existing copper sizes, drain pitch, and isolator location. That survey fee drops to zero when installation or repair proceeds (30-day repair cover).
  • Two paired SCM25YS-W fan coils cost S$30 per blower for routine maintenance (S$60 combined, 14-day warranty). Single units bill S$50, and three-plus units bill S$25 per blower.
  • Stale indoor odours or weak fan airflow clear with chemical servicing at S$70 each on paired heads (S$140 combined, 60-day cover). Single heads run S$80, while three-plus heads drop to S$60 each.
  • Blocked condensate trays call for full dismantled overhauls at S$125 per paired coil (90-day cover). One coil alone costs S$150, while three or more cost S$115 each.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

How much does Mitsubishi Heavy SCM25YS-W cost to run yearly in Singapore?
Under NEA's 1,805 kWh annual test profile, SCM25YS-W lists S$487 on the label and works out to S$562 yearly under SP Group's Q4 2026 tariff of 31.16 cents/kWh. Actual bills depend on thermostat hours and nightly load.
Can Mitsubishi Heavy SCM25YS-W cool a three-bedroom HDB flat plus living hall?
Rated 4.32 kW total capacity makes SCM25YS-W best suited for two bedrooms or a bedroom-and-study pairing rather than three busy zones plus a hall. Larger HDB flats normally step up to higher-kilowatt System 3 or System 4 condensers.
Does SCM25YS-W qualify for Singapore HDB Climate Vouchers?
Registered 5-tick multi-splits carrying active NEA certificates such as ELS-WKH-AC250132 qualify eligible Singapore HDB households for S$400 Climate Vouchers. Vouchers remain valid through December 2027 at participating registered retailers.
Why does SCM25YS-W show a 6.24 part-load COP versus 4.43 at full load?
Inverter multi-split compressors run most efficiently when throttling down to maintain temperature in one bedroom overnight. Keeping indoor coils clean preserves that 6.24 part-load efficiency instead of forcing continuous full-speed operation.