On this page
Quick summary
TOSOT TR32SAC28CUD secures five NEA ticks via ELS-STR-AC240033 until 27 March 2027, outputting 7.37 kW cooling at 5.63 weighted COP and 2,803 kWh annual test draw. Running cost translates to S$873 yearly under SP Group billing for larger HDB or condo households.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Assess TR32SAC28CUD Efficiency Data and SP Group Tariff Impact
Active on NEA's registry under ELS-STR-AC240033 through 27 March 2027, TOSOT TR32SAC28CUD earns five green ticks with 7.37 kW nominal cooling. Efficiency logs 4.98 COP at full load, 6.07 COP at part load, and 5.63 weighted COP.
Lab testing measures 2,803 kWh per year, displaying S$757 on the printed energy label. Electricity from SP Group costs 31.16 cents/kWh (including GST) in Q4 2026, bringing that annual benchmark to S$873 or nearly S$73 monthly.
Compare TR32SAC28CUD Capacity Against Residential Flat Needs
Check these verified ratings before choosing between 6.3 kW and 7.37 kW TOSOT condensers:
Scroll to see more columns
| Performance metric | NEA verified value | Late 2026 cost impact | Recommended flat profile |
|---|---|---|---|
| Certificate expiry | ELS-STR-AC240033 | Active until 27 Mar 2027 | HDB S$400 voucher qualifying tier |
| Total cooling output | 7.37 kW (~25,150 BTU/h) | 5.63 weighted COP rating | Supports 3 to 4 bedroom zones |
| Annual lab consumption | 2,803 kWh/yr | S$873/yr at Q4 SP Group rate | S$73/month at full benchmark |
| Commercial grant rule | 5-tick residential split | Below 5.8 COP EEG threshold | Use for homes, not SME claims |
Pair 7.37 kW Headroom with 4-Room HDB and Condo Layouts
That extra 1.07 kW over smaller 21-class condensers gives 4-room HDB, 5-room HDB, and compact three-bedroom condo layouts steadier cooling when three bedrooms plus a study run concurrently. Partial-load modulation peaks at 6.07 COP when only one room cools overnight.
Verify condo MCST bracket limits or HDB's 8.50A condenser amp cap and 80 kg bracket limit prior to installation. Always check that 22 SWG copper tubing and proper condensate slopes reach an internal floor trap cleanly.
Plan TR32SAC28CUD Inspection and Servicing Budgets Early
Four-unit multi-room homes benefit from volume servicing pricing across routine cleans and deep coil washes:
- Start with a S$30 on-site check to measure pipe lengths and ledge clearance; installation or repair waives that fee entirely (repairs carry 30 days of workmanship cover).
- Four indoor units bring general servicing to S$100 total (S$25 per coil on three-plus coils; two coils cost S$30 each, while a lone coil is S$50) with a 14-day warranty.
- Pair heavy west-facing rooms with chemical servicing at S$60 per coil on three-plus units, S$70 each on two, and S$80 on one (60-day workmanship warranty).
- Restore severely clogged blowers using full dismantled overhauls priced at S$115 per coil for three-plus coils, S$125 each for pairs, or S$150 solo with 90-day warranty terms.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Multi-split
Outdoor ledge dripping downstairs: split drain pipe stub
Split outdoor PVC condensate drain stub spilling backed-up water across the ledge

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends
Common Questions
How much does TOSOT TR32SAC28CUD add to monthly SP Group bills?
Why choose TOSOT TR32SAC28CUD over a 6.3 kW multi-split condenser?
Can HDB owners redeem S$400 Climate Vouchers on TOSOT TR32SAC28CUD?
Does TOSOT TR32SAC28CUD meet GoBusiness SME EEG multi-split criteria?
Sources
Sources checked 27 Nov 2026