On this page
Quick summary
GREE GWCD-MS28/O carries active NEA 5-tick certification ELS-GAS-AC250037 through 20 March 2028 at 7.15 kW cooling output, 5.7 weighted COP, and 2,721 kWh annual test draw. Its 5-tick rating unlocks S$400 HDB Climate Vouchers while keeping SP Group late-2026 test bills near S$848 yearly.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check Gree GWCD-MS28/O Efficiency Ratings and SP Group Annual Cost
Listed under NEA MELS certificate ELS-GAS-AC250037 until 20 March 2028, the outdoor GREE GWCD-MS28/O unit pairs 7.15 kW total cooling capacity with 5.07 full-load COP and 6.12 part-load COP. Its 5.7 weighted COP earns 5 Green Ticks and qualifies eligible HDB flats for S$400 Climate Vouchers until December 2027.
NEA's energy label prints 2,721 kWh yearly benchmark draw and a S$735 base estimate. At SP Group's Q4 2026 regulated tariff of 31.16 cents/kWh (GST-inclusive), that same 2,721 kWh benchmark totals S$848 annually, or about S$71 monthly under test duty.
Compare Gree GWCD-MS28/O Metrics and Singapore Flat Fit
Inspect verified NEA registration data alongside SP Group running numbers and installation allowances before locking indoor blower pairings:
Scroll to see more columns
| Verified specification | GREE GWCD-MS28/O value | Benchmark context | Owner takeaway |
|---|---|---|---|
| NEA certificate | ELS-GAS-AC250037 (5 ticks) | Valid to 20 Mar 2028 | Eligible for S$400 HDB voucher |
| Cooling & COP | 7.15 kW | 5.7 weighted COP | 5.07 full / 6.12 part COP | Strong part-load sleep savings |
| Annual test energy | 2,721 kWh/yr NEA label | S$735 NEA label estimate | S$848/yr at SP 31.16c/kWh |
| Typical flat pairing | 3-room or 4-room multi split | 22 SWG copper + 0.5-in foam | Supports staggered room schedules |
Match 7.15 kW Capacity to Singapore HDB and Condo Rooms
A 7.15 kW outdoor condenser supplies roughly 24,400 BTU total nominal output, fitting three 9,000 BTU bedrooms cleanly or two bedrooms plus one compact hall unit under staggered evening schedules. Part-load COP reaches 6.12 when only one or two bedrooms run overnight at 25 degrees.
Request 22 SWG thick copper piping wrapped in 0.5-inch closed-cell Armaflex insulation whenever installing new runs along exposed HDB service ledges. Proper vacuuming to 500 microns before opening R32 service valves protects compressor oil against moisture acid.
Keep outdoor condenser grilles free of laundry racks along HDB service yards so exhaust heat escapes smoothly without hurting high-COP efficiency.
Schedule Gree GWCD-MS28/O Servicing to Keep Efficiency High
Maintaining 6.12 part-load efficiency depends on dust-free blower wheels and unobstructed drain lines across every connected indoor head:
- General cleaning runs S$50 for one Gree unit or S$30 apiece on two units. Three-plus multi-split blowers cost S$25 each under 14-day cover.
- Grease-coated evaporators require chemical coil washing at S$80 on one head, S$70 per Gree head on two, or S$60 apiece across three-plus heads (60-day warranty).
- Deep drain slime clears through Gree strip-downs priced at S$150 single FCU, S$125 per Gree FCU on pairs, or S$115 apiece for three or more units (90-day cover).
- Erratic thermistor readings or blinking codes begin with an upfront S$30 fault check. That inspection fee drops to zero whenever Gree work proceeds.
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Daikin · Wall-mounted
Daikin J6 outdoor red LED: bad thermistor, not condenser
Open-circuit Daikin outdoor heat-exchanger thermistor halting multi-split cooling via outdoor safety protection while the inverter compressor stays healthy

LG · Wall-mounted
LG CH35 error: gas leak at the outdoor connections
Refrigerant leak at corroded outdoor unit pipe connections
Common Questions
How much does GREE GWCD-MS28/O cost per year on SP Group Q4 2026 tariffs?
Does GREE GWCD-MS28/O qualify for S$400 HDB Climate Vouchers?
Can GREE GWCD-MS28/O run three bedrooms plus a living-room blower together?
How often should owners service GREE GWCD-MS28/O indoor units to hold 5.7 COP?
Sources
Sources checked 27 Nov 2026