Quick summary
GREE GWCD-MS18/O holds active NEA 5-tick listing ELS-GAS-AC250036 until 18 March 2028 at 5.16 kW output and 5.74 weighted COP. Using SP Group's late-2026 rate (31.16 cents/kWh), its 1,986 kWh annual test draw reaches S$619 versus S$536 on the NEA label.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Check Gree GWCD-MS18/O Efficiency Ratings and SP Group Annual Math
Valid through 18 March 2028 under NEA certificate ELS-GAS-AC250036, GREE GWCD-MS18/O holds 5 ticks at 5.16 kW output. Lab tests record 4.92 full-load COP, 6.28 part-load COP, and 5.74 weighted COP.
Annual tested draw totals 1,986 kWh, shown as S$536 on the NEA label. At 31.16 cents/kWh (late-2026 GST-inclusive household tariff), 1,986 kWh equals S$619 annually. HDB households upgrading to active 5-tick hardware deduct S$400 via Climate Vouchers until Dec 2027.
Compare Gree GWCD-MS18/O Verified Figures and Flat Fit
Review verified GREE GWCD-MS18/O test figures alongside Singapore home sizing boundaries:
Scroll to see more columns
| Technical parameter | GREE GWCD-MS18/O figure | Tariff or test basis | Singapore flat sizing note |
|---|---|---|---|
| NEA MELS registration | ELS-GAS-AC250036 (5 ticks) | Expires 18 March 2028 | Eligible for S$400 HDB Climate Voucher |
| Cooling and COP band | 5.16 kW (~17,600 BTU/hr) | 4.92 full / 6.28 part / 5.74 COP | Strong 6.28 COP lowers overnight sleep draw |
| Annual test energy | 1,986 kWh per year | S$536 NEA label / S$619 SP Group | Reflects 31.16 cents/kWh GST-inclusive rate |
| Practical flat pairing | System 2 or light System 3 | Two 9k bedrooms plus study | Avoid full afternoon cooling across large halls |
Size GWCD-MS18/O Rooms and Copper Piping Before Installation
Delivering 5.16 kW output (around 17,600 BTU/hr), GWCD-MS18/O suits 2-room Flexi HDB flats, compact 3-room layouts, or paired condo bedrooms. Chilling two sunlit bedrooms plus a warm hall together forces compressors into lower 4.92 full-load efficiency.
Fit this condenser with fresh SWG 22 copper pipes, half-inch closed-cell foam sleeves, and steady PVC drain slopes. Nitrogen purging during brazing and full vacuuming keep compressor oil clean.
Schedule Gree GWCD-MS18/O Servicing and Fault Checks
Consistent evaporator and drain care keeps GWCD-MS18/O operating close to its 6.28 part-load benchmark:
- Book Snowflake's S$30 check whenever airflow weakens or error lamps blink. Proceeding with fixes cancels that visit fee and carries 30-day cover.
- Routine servicing keeps GREE blowers clean. Expect S$50 for one unit, S$30 per head on twin units, and S$25 each across three or more heads (14-day cover).
- In-place chemical washes clear sticky coil grease. Pricing runs S$80 for a lone room, S$70 apiece for two rooms, and S$60 apiece across three or more (60-day cover).
- Heavy drain sludge needs dismantled overhauls. Expect S$150 for a single FCU, S$125 per unit across pairs, or S$115 apiece across three-plus FCUs (90-day cover).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal