Quick summary
Midea MEZ-2M21E carries dual NEA 5-tick registrations ELS-MDS-AC250085 and ELS-MSP-AC250125 at 4.81 kW output, 5.55 weighted COP, and 1,886 kWh yearly test use. That equals S$588 annually on SP Group's Q4 31.16c/kWh billing tier, giving compact BTO and rental flats steady budget cooling.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Verify MEZ-2M21E NEA Listings and SP Group Running Costs
Midea MEZ-2M21E holds two active 5-tick NEA certificates: ELS-MDS-AC250085 (expiring 29 June 2028) and ELS-MSP-AC250125 (expiring 9 December 2028). Both certify 4.81 kW cooling across two indoor units.
Test efficiency measures 4.76 full load, 6.08 part load, and 5.55 weighted COP. Annual NEA test usage stands at 1,886 kWh and S$509 on the label.
Using Singapore's Q4 2026 rate (31.16 cents/kWh incl. GST), annual test draw totals S$588. Cooling one bedroom overnight uses 2.6 to 3.1 kWh. Monthly bills add S$24 to S$29 per room, or S$47 to S$56 for two.
Evaluate MEZ-2M21E for Compact BTO and Rental Flats
Budget-minded 2-room BTO buyers and 3-room landlords pick MEZ-2M21E for low purchase outlay and strong 4.81 kW output. Review key ownership facts below:
Scroll to see more columns
| Ownership criterion | Midea MEZ-2M21E spec | Tariff or rebate note | BTO or tenancy insight |
|---|---|---|---|
| Dual NEA registrations | ELS-MDS-AC250085 / ELS-MSP-AC250125 | Valid through Jun & Dec 2028 | Both carry identical 5-tick 4.81 kW ratings |
| COP performance | 5.55 weighted COP | 4.76 full | 6.08 part load | Strong reserve when two compact rooms run |
| SP Group electricity draw | 1,886 kWh/yr (NEA S$509) | S$588/yr at 31.16c/kWh | About S$24 to S$29/mo for 1 bedroom nightly |
| Climate Voucher offset | S$400 HDB rebate eligible | Applies through December 2027 | Requires residential non-transferable registration |
| Piping and tenancy horizon | 22 SWG copper + 0.5-inch foam | Years 6 to 8 major repair band | Log quarterly cleans in tenancy contracts |
Triage Midea E1 and EC Codes Without Premature Part Swaps
Early faults on rental System 2 sets usually follow skipped filter washes or thin pipework rather than compressor failure. Check display codes carefully before buying spare parts.
Code E1 (indoor-outdoor communication error) points to checking ledge terminals, power, and signal wires first. Test links before swapping boards.
Code EC warns of refrigerant leakage detection when coils stop chilling properly. Rinse clogged washable filters first, skip repeated breaker resets, and test leaks with dry nitrogen before adding R32.
Keep MEZ-2M21E Reliable with Fixed Check and Wash Rates
Specify thick 22 SWG copper upfront and put quarterly tenant servicing inside lease agreements. That prevents premature replacement quotes near year seven:
- Confirm faults with a S$30 site diagnosis first. Proceeding on the quote waives that fee, carrying 30 days repair warranty.
- Regular general washes cost S$50 for one fancoil or S$30 per unit for two. Multi-room sets with three or more coils run S$25 apiece (14-day cover).
- Flush damp lint mats and stale smells via chemical servicing at S$80 singly. Two units pay S$70 each, and three-plus pay S$60 each (60-day cover).
- Between tenancies, book dismantled chemical overhauls at S$150 for one room. Twin rooms cost S$125 each, while three-plus cost S$115 apiece (90-day cover).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Samsung · Wall-mounted
Coastal unit losing gas again: salt ate the pipe fitting
A corroded outdoor fitting thinned past the point where it can seal

Daikin · Cassette
Cassette not cooling: stuck gas-flow valve, not compressor
A flow-control valve stuck part-closed, restricting refrigerant to the indoor coil
Common Questions
Why does Midea MEZ-2M21E appear twice on Singapore's NEA register?
What does Midea MEZ-2M21E cost per month on SP Group rates in a 2-room BTO?
What should owners check first when Midea MEZ-2M21E flashes E1 or EC?
Can 2-room BTO homeowners apply S$400 Climate Vouchers to Midea MEZ-2M21E?
Sources