Quick summary
Midea MGP-2M21E holds NEA five-tick registration ELS-MDS-AC250083 until 22 June 2028, supplying 4.81 kW cooling capacity at 5.55 weighted COP and 1,886 kWh annual test consumption. At SP Group's 31.16-cent GST-inclusive tariff, that lab benchmark totals S$588 yearly versus S$509 on the label.
System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages
Verify MGP-2M21E NEA Ratings and Current SP Group Bill Math
Midea MGP-2M21E carries NEA listing ELS-MDS-AC250083 until 22 June 2028. It earns five energy ticks with 4.81 kW total output. Laboratory ratings show 4.76 full-load COP, 6.08 part-load COP, and 5.55 weighted COP.
Annual lab usage equals 1,886 kWh, printing S$509 on the green label. At SP Group's 31.16-cent tariff (GST included), yearly lab consumption totals S$588. Monthly spending averages near S$49 under standard test hours.
Real bedroom bills depend on room heat, thermostat settings, and nightly runtime. Running one bedroom at 25 degrees captures that thrifty 6.08 part-load curve. Eligible HDB flats also qualify for S$400 vouchers until end-2027.
Compare MGP-2M21E Certified Figures and Flat Suitability
Match MGP-2M21E test metrics against compact Singapore flat cooling loads before placing an order:
Scroll to see more columns
| Certificate detail | Midea MGP-2M21E data | Billing or grant impact | Practical Singapore fit |
|---|---|---|---|
| NEA register ID | ELS-MDS-AC250083 (5 ticks) | Valid until 22 June 2028 | Eligible for S$400 HDB vouchers |
| Cooling and COP | 4.81 kW | 5.55 weighted COP | 4.76 full; 6.08 part load | Shines during single-bedroom sleep |
| Annual kWh test | 1,886 kWh lab benchmark | S$509 label vs S$588 SP bill | Around S$49 monthly lab baseline |
| Recommended layout | Two 9,000 BTU bedrooms | 22 SWG copper + 0.5-in foam | Suits 2-room Flexi or 3-room flats |
Size 4.81 kW Capacity Across Compact HDB and Condo Rooms
At 4.81 kW cooling (around 16,400 BTU per hour), Midea MGP-2M21E fits two-room Flexi homes cleanly. Three-room HDB flats cooling two bedrooms and one-bedroom plus study condos match this output well.
Connecting a sunlit living room alongside two bedrooms stretches 4.81 kW thin on hot afternoons. Choose sturdy 22 SWG copper piping wrapped in half-inch foam sleeves. Pressure-test concealed lines with dry nitrogen before boxing trunking.
Plan Your MGP-2M21E Survey and Servicing Cadence
Check condenser ledge clearances before delivery and keep part-load efficiency high through Snowflake flat-rate care:
- Pre-install surveys cost S$30 for multi-splits or S$80 on VRV homes. Confirmed installation or repair work credits that fee back with a 30-day repair guarantee.
- General cleaning covers routine upkeep smoothly. Snowflake bills S$50 for one FCU, S$30 each on twin FCUs, or S$25 per coil across three or more blowers (14-day cover).
- Chemical washes strip stubborn dust film cleanly. Expect S$80 for one coil, S$70 per coil for pairs, or S$60 per coil across larger setups with 60-day cover.
- Complete overhauls dismantle choked blowers thoroughly. Expect S$150 on a lone coil, S$125 apiece on two coils, or S$115 apiece for three or more coils (90-day guarantee).
Diagnostic Cases for This Fault
Singapore jobs showing what we checked on-site before quoting parts or gas.

Mitsubishi Electric · Wall-mounted
Warm air with normal gas pressure: fouled coil, not low gas
Grease-choked indoor evaporator coil and dust-packed blower wheel causing poor temperature drop while refrigerant pressure stayed full

Gree · Wall-mounted
Gree F0 on a rusted condenser: refrigerant shortage
R32 refrigerant shortage triggering Gree F0 protection from corroded evaporator return bends