Midea MGP-3M28E 5-Tick kWh and Ownership Guide

Midea MGP-3M28E pairs 6.64 kW multi-split cooling with 5.98 weighted COP under NEA record ELS-MSP-AC250123. Homeowners can weigh monthly SP Group running costs, room-load limits, and flat-rate upkeep below.

On this page

Quick summary

NEA certificate ELS-MSP-AC250123 registers Midea MGP-3M28E at 5 ticks, 6.64 kW cooling, 5.98 weighted COP, and 2,476 kWh yearly draw through 3 December 2028. Applying SP Group's Q4 2026 GST-inclusive tariff (31.16 cents/kWh) puts that annual figure at S$772 before S$400 Climate Voucher rebates.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Verify Midea MGP-3M28E Ratings and Late 2026 Electricity Bills

NEA registration ELS-MSP-AC250123 lists Midea MGP-3M28E as a 5-tick multi-split until 3 December 2028. Total rated capacity stands at 6.64 kW. Full-load efficiency hits 5.13 COP, part-load efficiency reaches 6.54 COP, and weighted COP equals 5.98.

Official lab testing records 2,476 kWh annually, printed as S$669 on the green label. SP Group bills Q4 2026 households 31.16 cents/kWh once GST applies. That regulated tariff raises the annual lab benchmark to S$772.

Actual overnight bedroom consumption stays much lighter. Cooling one 9,000 BTU room for eight sleep hours at 25 degrees draws roughly 2.8 to 3.2 kWh. That single-room load adds S$26 to S$30 monthly, while two sleep zones cost S$50 to S$58.

Compare MGP-3M28E Benchmark Figures and Flat Suitability

Review MGP-3M28E output numbers, electricity assumptions, and HDB or condo sizing limits side by side:

Scroll to see more columns

Compare MGP-3M28E benchmark figures and flat suitability summary table
Evaluation areaMGP-3M28E specMonthly or yearly costSingapore flat takeaway
NEA listing ELS-MSP-AC2501235 ticks, 6.64 kW, COP 5.98Valid until 3 Dec 2028Qualifies for S$400 HDB Climate Vouchers
Standard NEA test draw2,476 kWh annual test cycleS$669 label; S$772 SP rateCalculated at Q4 2026 31.16c GST rate
Nightly sleep load1 or 2 rooms at 25 degreesS$26-S$30 (1) or S$50-S$58 (2)Part-load COP 6.54 cuts overnight waste
Simultaneous room cap~22,650 BTU/h total outdoorMatches 3-room or 4-room flatsAvoid full-blast daytime living plus 3 rooms

Match MGP-3M28E Capacity to HDB and Condo Room Loads

An output of 6.64 kW provides roughly 22,650 BTU/h of combined cooling power. Three 9,000 BTU bedroom blowers run steadily at night once afternoon solar load recedes. Most three-room HDB flats and compact two-bedder condos fit this curve cleanly.

Connecting one 18,000 BTU living-room blower plus two bedroom units also works when occupants stagger daytime and night schedules. Pair the condenser with 22 SWG copper piping and thick closed-cell insulation for durable HDB runs. Eligible HDB households further offset upgrade costs using S$400 Climate Vouchers before December 2027 ends.

Plan Midea MGP-3M28E Servicing and Pre-Install Surveys

Clean evaporator fins and sound piping keep MGP-3M28E close to its 6.54 part-load COP rating across humid weather:

  • Pre-install site inspections cost S$30 and verify bracket spacing, copper sizing, and drain fall. That inspection fee drops off once installation or repair proceeds.
  • Three-blower general servicing costs S$25 per FCU with a 14-day warranty. Solitary units cost S$50, and dual setups bill S$30 per unit.
  • Wash individual coils chemically at S$80, dual blowers at S$70 each, or three-head suites at S$60 per unit (60-day cover).
  • Dismantled chemical overhauls restore choked drain trays under a 90-day warranty. Three-unit homes pay S$115 per coil, pairs pay S$125 each, and solo jobs cost S$150.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

How much electricity does Midea MGP-3M28E use each year in Singapore?
Official NEA testing under ELS-MSP-AC250123 logs 2,476 kWh annually, which totals S$772 at SP Group's Q4 2026 GST-inclusive tariff of 31.16 cents/kWh. Actual household bills vary directly with nightly room count, afternoon sun, and filter cleanliness.
Can Midea MGP-3M28E cool a living room and three bedrooms simultaneously?
With 6.64 kW total outdoor capacity, MGP-3M28E prioritizes three bedrooms overnight or living-room cooling during the day rather than four heavy zones at once. Larger four-zone daytime loads typically call for an 8.86 kW condenser instead.
Does Midea MGP-3M28E qualify for HDB Climate Vouchers in 2026?
Holding a verified 5-tick NEA rating under ELS-MSP-AC250123 lets eligible HDB households apply S$400 in Climate Vouchers before December 2027. Check your flat address eligibility on the official NEA portal prior to placing a supplier order.
How often should homeowners service a Midea MGP-3M28E multi-split system?
Scheduling general servicing every three months keeps indoor fins clear and protects part-load efficiency near 6.54 COP. Homes running daily living-room hours or near renovation dust usually need annual chemical cleaning to keep drain trays clear.

Sources

Sources checked 27 Nov 2026

  1. NEA Registered Goods PortalNational Environment Agency (NEA) · Checked 27 Nov 2026
  2. SP Group Electricity Tariff InformationSP Group · Checked 27 Nov 2026
  3. NEA Climate Vouchers Aircon EligibilityNational Environment Agency (NEA) · Checked 27 Nov 2026