Midea 6.97 kW 5-Tick Multi Split kWh and Bill Guide

Certificate ELS-MSP-AC260004 rates the Midea MOU24-HVN32E(SG) multi split at 6.97 kW cooling, 5.7 weighted COP, and 2,581 kWh yearly. Review updated bill math, room-pairing limits, and flat upkeep rates below.

On this page

Quick summary

Midea MOU24-HVN32E(SG) holds NEA 5-tick certificate ELS-MSP-AC260004 until 11 January 2029 at 6.97 kW output, 5.7 weighted COP, and 2,581 kWh yearly test draw. That consumption totals S$804 annually under current SP Group billing, fitting three HDB bedrooms with S$400 voucher support.

Request an installation quote on WhatsApp

System 2 installed from $2,600 (22 SWG copper) · $30 site survey waived on install · View packages

Verify Midea 6.97 kW Multi-Split Efficiency and Electricity Math

Registered under NEA certificate ELS-MSP-AC260004 until 11 January 2029, Midea MOU24-HVN32E(SG) achieves 5 ticks at 6.97 kW capacity. Full-load efficiency hits 5.32 COP. Part-load efficiency climbs to 5.95 COP, producing a 5.7 weighted COP.

Official test draw totals 2,581 kWh yearly, which NEA displays as S$697 using its fixed label estimate. Applying SP Group's GST-inclusive Q4 2026 tariff of 31.16 cents/kWh brings that test benchmark to S$804 annually.

Compare Rated Specs Against Real Home Running Profiles

Inspect verified ELS-MSP-AC260004 figures alongside practical Singapore household usage notes:

Scroll to see more columns

Compare rated specs against real home running profiles summary table
Specification lineVerified NEA figureSingapore cost contextBuyer takeaway
Certificate & expiryELS-MSP-AC260004 (5 ticks)Eligible for S$400 HDB voucherRegistration valid through 11 Jan 2029
Cooling & COP balance6.97 kW | 5.7 weighted COP5.32 full load / 5.95 part loadStrong efficiency during overnight sleep hours
Annual test energy2,581 kWh yearly benchmarkS$697 NEA label vs S$804 SP tariffCalculated on 31.16 cents/kWh rate
HDB install spec22 SWG copper + Armaflex laggingS$30 site check (waived on work)Prevents condensation drips on ceiling runs

Match 6.97 kW Outdoor Capacity to HDB and Condo Rooms

Total outdoor cooling equals 6.97 kW, roughly 23,780 BTU/hr across connected rooms. That output drives three bedrooms smoothly together. Nighttime operation near 25 degrees captures strong 5.95 part-load efficiency.

Adding a large 18,000 BTU hall unit alongside bedrooms stretches total capacity on sunny afternoons. Stagger daytime living cooling against sleeping hours for steady comfort. Eligible HDB buyers may apply S$400 Climate Vouchers toward 5-tick sets before January 2028.

Plan Flat-Rate Midea Servicing and Check Cadences

Keep Midea 5-tick efficiency high across humid years using transparent flat-rate upkeep:

  • General cleaning keeps fins clear quarterly. One blower costs S$50, pairs bill S$30 each, and sets with three units charge S$25 per head (14-day warranty).
  • Chemical servicing strips stubborn drain slime early. Single blowers pay S$80, two units total S$140, and three-head homes pay S$60 apiece (60-day warranty).
  • Chemical overhauls dismantle neglected coils completely. Solo teardowns cost S$150, dual teardowns bill S$125 per coil, and three-unit jobs run S$115 per head with 90-day warranty cover.
  • Diagnostic visits cost S$30 upfront and drop off your repair bill with 30-day warranty coverage.

Diagnostic Cases for This Fault

Singapore jobs showing what we checked on-site before quoting parts or gas.

Common Questions

Why does the Midea MOU24-HVN32E(SG) NEA label say S$697 while SP Group math shows S$804?
NEA energy labels estimate yearly dollars using a standardised 27 cents/kWh reference rate so buyers compare models fairly. Multiplying the verified 2,581 kWh test draw by SP Group's Q4 2026 tariff of 31.16 cents/kWh yields S$804.
Can Midea MOU24-HVN32E(SG) power three bedrooms and a living room simultaneously?
Driving four indoor units simultaneously stretches a 6.97 kW condenser beyond rated capacity on hot afternoons, splitting cooling unevenly. Staggering living daytime use against night bedrooms keeps full-load strain low.
Does Midea MOU24-HVN32E(SG) qualify for S$400 Singapore Climate Vouchers?
Listed under verified 5-tick registration ELS-MSP-AC260004 until 11 January 2029, MOU24-HVN32E(SG) meets NEA 5-tick rules. Eligible HDB flat households can apply S$400 Climate Vouchers at participating suppliers through December 2027.
What copper pipe thickness protects Midea multi-split efficiency in Singapore flats?
Installing 22 SWG copper tubing wrapped in half-inch closed-cell Armaflex insulation stops moisture sweat inside ceiling trunking and resists pinhole leaks. Correct vacuuming and flare torque keep rated 5.95 part-load COP steady.